| Magnet | Optimal working volume | Description |
|---|
DynaMag™-2
 | 10 µL–2,000 µL (This magnet replaces the Dynal® MPC-S magnet) | - Holds 16 (1.5–2 mL) microfuge tubes.
- 8 positions on each side of the rack.
- Top rack can be quickly removed from the magnet in the base, ready for vortexing, rotation or manual sample shaking. A center pin in the rack ensures equal vortexing of all tubes.
- Excellent control and visibility of your isolations.
|
SampleRack for DynaMag™-2
 | (see above) | - The removable tube-holder plastic rack for the DynaMag™-2 is also available as a separate item.
- An additional SampleRack minimizes the need to move tubes between racks.
- The SampleRack can be placed on the bench, in the fridge or in the incubator.
|
DynaMag™-Spin
 | 10 µL–1,500 µL | - Holds 6 (1.5 mL) microfuge tubes.
- Circular top rack can be quickly removed from the magnet in the base, ready for vortexing or manual sample shaking.
- Good control of your isolations.
|
DynaMag™-5
 | 1 mL–5 mL | - Flexible magnet: Handles many different tube sizes (11-16 mm in diameter, e.g. flow tubes and blood collection tubes) in a more functional way.
- More samples: Takes 8 tubes at a time of 1 mL to 5 mL volumes.
- Removable SampleRack: The tubes can be kept in the same space during the whole isolation process and beyond, just lift the whole SampleRack on/off the magnet base during handling. Buy an extra SampleRack and double the capacity.
|
SampleRack for DynaMag™-5 
| | - The removable tube-holder plastic rack for the DynaMag™-5 is also available as a separate item.
- Additional SampleRacks may be useful when there are multiple users of the DynaMag™-5 magnet or when processing more than 8 samples at a time.
- The SampleRack can be placed on the bench, in the fridge or in the incubator.
|
DynaMag™-15
 | 1 mL–15 mL (This magnet replaces the Dynal MPC™-L and Dynal MPC-15 magnets) | - Holds 4 standard 15 ml tubes, or when flipped 180 degrees holds 4 x 5 mL tubes used in flow cytometry.
- Can be used for any starting sample in combination with all types of Dynabeads®.
- Good control and visibility of your isolations.
|
DynaMag™-50
 | 5 mL–50 mL (This magnet replaces the Dynal MPC-50 magnet) | - Holds 2 x 50 mL tubes.
- Can be used for any starting sample in combination with all types of Dynabeads®.
- Good control and visibility of your isolations.
|
DynaMag™-96 Side

(magnified below)
 | 5 µL–200 µL (This magnet replaces the Dynal MPC®-9600 magnet) | - Holds PCR-Style Strips & Plates:
- PCR strips (8 & 12 well)
- non-skirted 96-well plates
- ½-skirted (200 µL) 96-well plates
- 48 & 96 microtubes for the Applied Biosystems GeneAmp® PCR System
- Pulls beads to the side of each well.
- For manual & automated work.
- Footprint same as a 96-well plate.
- Features 13 columns.
- In conjunction with an automated platform, the 13th column enables sample mixing without physically interacting with the sample.This is performed by repeatedly shifting the plate from the left-most to the right-most position & vice-versa.
|
DynaMag™-96 Bottom
 (magnified below)

| 5 µL–200 µL (This magnet replaces the Dynal MPC®-96B magnet) | - Holds PCR-Style Strips & Plates:
- PCR strips (8 & 12 well)
- non-skirted 96-well plates
- ½-skirted (200 µL) 96-well plates
- 48 & 96 microtubes for the Applied Biosystems GeneAmp® PCR System
- Pulls beads to the bottom of each well.
- For manual & automated work.
- Footprint same as a 96-well plate.
|
DynaMag™-96 Side Skirted  (magnified below)

| 5 µL–200 µL | - Holds skirted 96-well PCR-Style plates.
- Pulls beads to the side of each well.
- For automated work.
- Footprint size same as a 96-well plate.
Also works with the following cell culture plates:- 96-well round bottom plates
- 96-well flat bottom plates
- 24-well plates
- 12-well plates
- 6-well plates
- not recommended for use with 48 well plates
|
DynaMag™ CTS™ 
| - For closed sterile blood bags
- Scalable volumes: 50 mL to 330 mL in static separations.
- >10 L in continuous flow separations following T cell expansion protocols.
| - Positively isolate bead-bound cells e.g. for subsequent stimulation/ expansion of T cells with Dynabeads® CD3/CD28 CTS™, and for removal of the beads following the expansion protocol.
|