Magnets for Molecular and Cell Separation Applications
| DynaMag™ magnets isolate any target in combination with Dynabeads®. Your waiting time is minimized as these powerful magnets quickly pull your Dynabeads®-bound target to the tube wall. The DynaMag™ magnets ensure optimal working positions and are functionally adapted to suit your workflow. Want a cool lab mixer ? Check out the HulaMixer™ Sample Mixer! |
Faster isolations
General features:
|
Better working positions![]() |
Magnet Selection Guide for Dynabeads
| Magnet | Optimal working volume | Description | ||
|---|---|---|---|---|
DynaMag™-2![]() | 10 µl - 2,000 µl This magnet replaces the Dynal® MPC-S magnet. | • Holds 16 (1.5 - 2 ml) microfuge tubes. • 8 positions on each side of the rack. • Top rack can be quickly removed from the magnet in the base, ready for vortexing, rotation or manual sample shaking. A center pin in the rack ensures equal vortexing of all tubes. • Excellent control and visibility of your isolations. | ||
SampleRack for DynaMag™-2![]() | (see above) | • The removable tube-holder plastic rack for the DynaMag™-2 is also available as a separate item. • An additional SampleRack minimizes the need to move tubes between racks. • The SampleRack can be placed on the bench, in the fridge or in the incubator. | ||
DynaMag™-Spin![]() | 10 µl - 1,500 µl | • Holds 6 (1.5 ml) microfuge tubes. • Circular top rack can be quickly removed from the magnet in the base, ready for vortexing or manual sample shaking. • Good control of your isolations | ||
DynaMag™-15![]() | 1 ml - 15 ml This magnet replaces the Dynal MPC™-L and Dynal MPC-15 magnets | • Holds 4 standard 15 ml tubes, or when flipped 180 degrees holds 4 x 5 ml tubes used in flow cytometry. • Can be used for any starting sample in combination with all types of Dynabeads. • Good control and visibility of your isolations | ||
DynaMag™-50![]() | 5ml - 50 ml This magnet replaces the Dynal MPC-50 magnet. | • Holds 2 x 50 ml tubes • Can be used for any starting sample in combination with all types of Dynabeads. • Good control and visibility of your isolations | ||
| DynaMag™-96 Side (magnified below) | 5 µl - 200 µl This magnet replaces the Dynal MPC®-9600 magnet | • Holds PCR-Style Strips & Plates: • PCR strips (8 & 12 well) • non-skirted 96-well plates • ½-skirted (200µl) 96-well plates • 48 & 96 microtubes for the Applied Biosystems GeneAmp® PCR System • Pulls beads to the side of each well. • For manual & automated work. • Footprint same as a 96-well plate. • Features 13 columns. | ||
| DynaMag™-96 Bottom (magnified below) | 5 µl - 200 µl This magnet replaces the Dynal MPC®-96B magnet | • Holds PCR-Style Strips & Plates: • PCR strips (8 & 12 well) • non-skirted 96-well plates • ½-skirted (200µl) 96-well plates • 48 & 96 microtubes for the Applied Biosystems GeneAmp® PCR System • Pulls beads to the bottom of each well. • For manual & automated work. • Footprint same as a 96-well plate. | ||
| DynaMag™-96 Side Skirted (magnified below) | 5 µl - 200 µl | • Holds skirted 96-well PCR-Style plates. • Pulls beads to the side of each well. • For automated work. • Footprint size same as a 96-well plate. Also works with the following cell culture plates: • 96-well round bottom plates • 96-well flat bottom plates • 24-well plates • 12-well plates • 6-well plates • not recommended for use with 48 well plates | ||
DynaMag™ CTS™![]() | For closed sterile blood bags Scalable volumes: 50mL to 330 ml in static separations. >10 L in continuous flow separations following T cell expansion protocols. | Intended for use with the Dynabeads® CTS™ product portfolio in clinical research. Positively isolate bead-bound cells e.g. for subsequent stimulation/ expansion of T cells with Dynabeads® CD3/CD28 CTS™, and for removal of the beads following the expansion protocol. | ||