LIVE/DEAD® Fixable Dead Cell Stains
|
These flow cytometry-based kits provide you with tools that are:
- Fixable—Staining retained after fixation for simple live/dead analysis with intracellular phenotyping
- Simple—Fits into almost any staining and phenotyping protocols
- Flexible—Seven colors from which to choose for UV, 405, 488, or 633 lasers
Choose the Right Kit
| LIVE/DEAD® Fixable Dead Cell Stain Kit | Excitation (nm) | Emission (nm) | Cat. No. |
|---|---|---|---|
| Blue Dead Cell Stain | UV | 450 | L23105 |
| Violet Dead Cell Stain | 405 | 440 | L34955 |
| Aqua Dead Cell Stain | 405 | 525 | L34957 |
| Yellow Dead Cell Stain | 405 | 570 | L34959 |
| Green Dead Cell Stain | 488 or 532 | 530 | L23101 |
| Red Dead Cell Stain | 488 or 561 | 615 | L23102 |
| Far Red Dead Cell Stain | 633/635 | 665 | L10120 |
| Near-IR Dead Cell Stain | 633/635 | 775 | L10119 |
| Dead Cell Stain Sampler | Various | 450–775 | L34960 |
How It WorksMolecular Probes® LIVE/DEAD® Fixable Dead Cell Stain Kits are based on the reaction of a fluorescent reactive dye with cellular proteins (amines).
The difference in fluorescence intensity between the live- and dead-cell populations is typically greater than 50-fold, thereby allowing complete, simultaneous discrimination between the 2 cell populations. |
Assay Principle
|
Key Advantages
The LIVE/DEAD® Fixable Dead Cell Stain Kits offer a broad range of advantages:
- Reliable, Post-Fixation Measurement of Viability — Common nucleic acids stains like propidium iodide (PI ) tend to leak out of cells after washing and after fixation all cells will stain positive. With the LIVE/DEAD® Fixable Dead Cell Stain Kits, the “snapshot” of viability taken prior to antibody or other reagent staining is maintained throughout the staining process, and beyond.
- Accurate Intracellular Staining Measurements — Induced cytokine and signaling responses are notoriously difficult to detect due to low stain signals, and this is complicated by nonspecific binding of reagents to dead cells.
- Removal of False Positive Dead Cells — Other methods often give false positive results as they tend to bind nonspecifically to many reagents. However, live- vs. dead-cell staining is unequivocal using LIVE/DEAD® Fixable Dead Cell Stain Kits.
- Flexibility in Experimental Design — Multiple colors for four major lasers means that these single-color assays use only one channel of one laser on a flow cytometer, leaving other channels available for more common reagents and multicolor experiments.
![]() | Live-cell gating using the LIVE/DEAD® Fixable Violet Dead Cell Stain Kit eliminates staining artifacts from analysis. In a comparison between live-cell gating using scatter (A), and live-cell gating using LIVE/DEAD® Fixable Violet dye (B), staining artifacts using scatter gating are illustrated. The significant number of dead cells in subsequent analysis using scatter (C) are noted, as compared to the use of the LIVE/DEAD® Fixable Violet dye (D) to eliminate dead cells. Reproduced with permission from Elsevier (Amine reactive dyes: an effective tool to discriminate live and dead cells in polychromatic flow cytometry. Perfetto SP, et.al., J Immunol Methods 313:199(2006)). |
Need Compensation?
Experts agree that the ArC™ Amine Reactive Compensation Bead Kit is the perfect tools for setting up the compensation requirements of the LIVE/DEAD® Fixable Dead Cell Stains in your experiments.
| Product | Quantity | Cat. No. |
|---|---|---|
| ArC™ Amine Reactive Compensation Bead Kit | 1 Kit | A10346 |