Total Protein Visualization

Protein Characterization

Simple-to-use stains for total protein visualization
 

A fast, sensitive, and safe Colloidal Coomassie® G-250–based stain for nanogram-level detection of proteins. Click here for more information on SimplyBlue™ SafeStain

SimplyBlue
SimplyBlue™ SafeStain
 

A Mass Spectrometry-Compatible Silver Stain ideal for colorimetric staining of low-abundance proteins, with sensitivity to sub-nanogram levels. Click here for more information on SilverQuest™ Silver Stain

SilverQuest
SilverQuest™ Silver Stain
 

A highly sensitive, ready-to-use fluorescent stain for the detection of low abundance proteins in 1-D or 2-D gels. Click here for more information on SYPRO® Ruby and Multiplexed Proteomics Technology

Ruby Stains
SYPRO® Ruby Protein Gel Stain
 

A ready-to-use fluorescent stain that provides fast, simple, sensitive staining of proteins in less than an hour – no separate fixation or destaining steps are required. Click here for more information on Coomassie® Fluor ™ Orange

Coomassie
Coomassie® Fluor™ Orange Stain

Table 1. Major stains for total protein

         

SimplyBlue™ SafeStain SilverQuest™ Silver Stain SYPRO® Ruby Protein Gel Stain Coomassie® Fluor™ Orange
Type of stain Ready-to-Use colloidal Coomassie® G-250 Ready-to-Use, MS compatible silver stain Fluorescent total protein stain – Ready-to-Use Fluorescent total protein stain – Ready-to-Use
Detection / Imaging Visual – Colorimetric Visual – Colorimetric UV transilluminator, Blue Light Box or a Laser Scanner UV transilluminator, Blue Light Box or a Laser Scanner
Sensitivity To 7 ng BSA Sub-nanogram (To 0.3 ng) Sub-nanogram (To 0.25-0.5 ng ) To 4-8 ng/band
Linear dynamic range 7-70 ng 1-10 ng 0.25-1000 ng 4-1000 ng
MS -compatibility Yes Yes Yes Yes
Total staining time 12 minutes (microwave protocol) < 60 minutes (microwave protocol) 90 minutes (microwave protocol) 30-60 minutes (Standard protocol)

3 hours (Standard protocol) 90 minutes (Standard protocol) Overnight (Standard protocol for Large Format gels)
Protocol summary Rinse, stain, water-based destain Fix, sensitize, wash, stain, wash, develop, and stop Fix, stain, and wash Fix and stain, in one step
Shipping/Storage Store at Room Temperature Store at Room Temperature Store at Room Temperature Store at Room Temperature
Stability 6 months 6 months 1 year (at least 9 months) 6 months
For densitometry Yes Not recommended Integration of fluorescent signal Integration of fluorescent signal
Staining membranes PVDF No Use SYPRO ® Ruby Blot Stain No
Cat. no. LC6060, LC6065 LC6070 S12001, S12000, S21900 C33250, C33251