BioTek Instruments

BioTek’s Synergy™ 4 and Synergy™ 2 multi-mode microplate readers have received the LanthaScreen® Certified Plus designation from Life Technologies which ensures that these readers are validated to strict standards in instrument setup and assay performance.

Before using LanthaScreen® Terbium and Europium assays

Test your plate reader set-up

These technical notes provide a method for verifying that a fluorescent plate reader is able to detect a change in time-resolved fluorescence energy transfer (TR-FRET) signal, confirming proper instrument set-up and a suitable response. The method is independent of any biological reaction or equilibrium and uses reagents that are on-hand for the LanthaScreen® assay.

Download Terbium assay application note

Download Europium assay application note

Synergy™ H4 Hybrid Multi-Mode Microplate Reader


 

Instrument Configuration:

Assay Technology Adapta® &
LanthaScreen®
Europium
GeneBLAzer®LanthaScreen®
Terbium
Omnia®Predictor™Z'-LYTE®
ModalityTR-FRETFRET (bottom)TR-FRETFI (kinetic)FPFRET
Setup Guide

Application NoteViewViewViewViewViewView
Poster-ViewViewViewViewView
Excitation Filter (18 mm) 340/30400/30340/40360/40530/25 400/30 
Emission 1 Filter (18 mm) 620/10460/40495/10485/20590/35460/40 
Emission 2 Filter (18 mm) 665/8528/20520/25 590/35 528/20 
Dichroic Mirror 400 400400 570435 

 

Synergy™ 2 Multi-Mode Microplate Reader


 

 

Instrument Configuration:

Assay Technology Adapta® &
LanthaScreen®
Europium
GeneBLAzer®LanthaScreen®
Terbium
Omnia®Predictor™Z'-LYTE®
ModalityTR-FRETFRET (bottom)TR-FRETFI (kinetic)FPFRET
Setup Guide

Application NoteViewViewViewViewViewView
Poster-ViewViewViewViewView
Excitation Filter (18 mm) 340/30400/30340/30360/40530/25 400/30 
Emission 1 Filter (18 mm) 620/10460/40495/10485/20590/35460/40 
Emission 2 Filter (18 mm) 665/8528/20520/25 590/35 528/20 
Dichroic Mirror 400 400400 570 

Synergy™ HT Multi-Mode Microplate Reader

 

Instrument Configuration:

Assay Technology Adapta® &
LanthaScreen®
Europium
GeneBLAzer®LanthaScreen®
Terbium
Omnia®Predictor™Z'-LYTE®
ModalityTR-FRETFRET (bottom)TR-FRETFI (kinetic)FPFRET
Setup Guide

Reader not compatible

 -

Reader not compatible

-

Reader not compatible

-

Application Note-View---View
Poster------
Excitation Filter (18 mm) 400/30 340/30 400/30 
Emission 1 Filter (18 mm) 460/40 485/20 460/40 
Emission 2 Filter (18 mm) 528/20   528/20 

FLx800™ Fluorescence Microplate Reader

 

Instrument Configuration:

Assay Technology Adapta® &
LanthaScreen®
Europium
GeneBLAzer®LanthaScreen®
Terbium
Omnia®Predictor™Z'-LYTE®
ModalityTR-FRETFRET (bottom)TR-FRETFI (kinetic)FPFRET
Setup Guide

Reader not compatible

Reader not compatible

Reader not compatible

Application Note------
Poster-View-View-View
Excitation Filter (18 mm) 400/30 360/40 400/30 
Emission 1 Filter (18 mm) 460/40 485/20 460/40 
Emission 2 Filter (18 mm) 528/20   528/20 



* Filters (diameter) shown as center wavelength/bandwidth (nm) & dichroic mirrors shown as cutoff wavelength (nm). Contact BioTek Instruments for information on ordering filters and dichroic mirrors suitable with the microplate readers listed above.                    
                                       
Synergy™ and FLx800™ are trademarks of BioTek Instruments.