SPoT-Light® CISH Hybridizer
![]() | Convenient, automated, and simple chromogenic in situ hybridization The SPoT-Light® CISH Hybridizer is an easy-to-use instrument that automates the denaturation and hybridization steps involved in chromogenic in situ hybridization (CISH) procedures (Figure 1). The programmable SPoT-Light® CISH Hybridizer reduces hands-on time by more than 50% and provides walk-away convenience that saves you valuable time. |
|
Flexible Use
The SPoT-Light® CISH Hybridizer is “user-tolerant” and flexible to use. The lid seals tightly when closed, providing optimal chamber humidity so sample specimens do not dry out. Load 12 slides or just one at a time. The SPoT-Light® CISH Hybridizer maintains uniform and accurate consistency across all slide positions, at all times. Slides can be easily added or removed with just one hand using the convenient built-in slide guides.
|
![]() Figure 1. CISH detection of EGFR gene amplification in a glioblastoma tumor using the SPoT-Light® CISH Hybridizer |
User Benefits
|
Convenient user-programmable settings and easy-to-use features
- 40 user-defined programmable settings and 3 operating modes—denaturation/hybridization, hybridization, and fixed temperature
- Easy-to-read backlit display
- Simple programmable numeric keypad
- Convenient, one-handed slide removal using the built-in slide guides
- Fixed-temperature slide warmer option
- Compact size that frees up bench top space
SPOT-Light® CISH Hybridizer Specifications
Catalog Number: 76-2000 (120V) 76-2001 (240V)
Capacity: Up to 12 slides
Processing Time: 0-100 hours
Number of Programs: 40
Temperature Range: Programmable 30-99 ºC
Ramp Time: 37 – 95ºC in less than 3 minutes
Cooling Time: 95 - 45ºC in less than 6 minutes
Electrical: 120 VAC @ 3.0A(76-2000); 240 VAC @ 1.6A (76-2001)
Dimensions:
Capacity: Up to 12 slides
Processing Time: 0-100 hours
Number of Programs: 40
Temperature Range: Programmable 30-99 ºC
Ramp Time: 37 – 95ºC in less than 3 minutes
Cooling Time: 95 - 45ºC in less than 6 minutes
Electrical: 120 VAC @ 3.0A(76-2000); 240 VAC @ 1.6A (76-2001)
Dimensions:
Environmental:
- Depth 45.1 cm
- Width 22.8 cm
- Height 14.6 cm
- Weight 8.5 kg
Regulatory: UL and CE marked
- Indoor use
- Altitude up to 2000m
- Temperature 15ºC to 40ºC
- Maximum relative humidity 80% for temperatures up to
- 15ºC decreasing linearly to 50% relative humidity at 40ºC;
- Main supply voltage fluctuations not to exceed +/- 10% of the nominal voltage; Transient over-voltages according to installation category II; Pollution degree 2