Sytox® Blue

Trypan Blue Stain 0.4%, for use with the Countess® Automated Cell Counter

Category: Products & Services > Labeling & Detection Products > Cell Stains > Other Cell Stains

Trypan blue stain is a well-accepted method for staining dead cells. It can enter into cells with compromised membranes and is the method used with the Countess® automated cell counting platform.
Catalog: T10282
Size: 2 × 1 ml

Streptavidin, Marina Blue® conjugate

Category: Products & Services > Antibodies & Secondary Detection Reagents > Avidin, Streptavidin & Biotin > Streptavidin

Our streptavidin, Marina Blue™ conjugate is a bright, blue-fluorescent probe with excitation/emission ~365/460 nm. Streptavidin is a nonglycosylated biotin-binding protein that is isolated from bacteria and has a near-neutral isoelectric point. It is widely used to detect biotinylated probes, because it reportedly exhibits less nonspecific binding than does the glycosylated, biotin-binding protein, avidin.
Catalog: S-11221
Size: 1 mg

F4/80 Rat Anti-Mouse mAb (clone BM8), Pacific Blue™ Conjugate

Category: Products & Services > Antibodies & Secondary Detection Reagents > Primary Antibodies > Protein Specific Primary Antibodies

The F4/80, clone BM8, Pacific Blue™ dye conjugate is a monoclonal rat antibody that is specific to mouse F4/80 and recognizes the expressed product of the Emr1 gene. Our Pacific Blue™ dye is optimally excited by the violet laser and conjugates of this dye are strongly fluorescent even at neutral pH. Pacific Blue™ and Pacific Orange™ dye conjugates can be simultaneously excited at 405 nm and emit at 455 nm and 551 nm, respectively, facilitating two-color analysis. Antibody Specifications Description: F4/80, Rat IgG2a monoclonal Label: Pacific Blue™ dye Validated Application: Flow Cytometry Spec...
Catalog: MF48028
Size: 1 ml

LysoSensor™ Yellow/Blue DND-160 - Special Packaging

Category: Products & Services > Labeling & Detection Products > Cell Stains > Organelle Stains

LysoSensor™ Yellow/Blue DND-160 is a ratiometric probe that can be used to measure the pH of acidic organelles, such as lysosomes. The LysoSensor dye produces blue fluorescence in neutral environments, but changes to yellow fluorescence in more acidic environments. The pK a of LysoSensor Yellow/Blue DND-160 is ~4.2.
Catalog: L-7545
Size: 20 × 50 µl

SYTOX® Green Nucleic Acid Stain - 5 mM Solution in DMSO

Category: Products & Services > Labeling & Detection Products > Cell Stains > Nucleic Acid Cell Stains

SYTOX® Green nucleic acid stain is an excellent green-fluorescent nuclear and chromosome counterstain that is impermeant to live cells, making it a useful indicator of dead cells within a population. • Impermeant to live cells • Excitation/Emission: 504/523 nm • Use with 488 Argon-ion laser • Works with mammalian cells and both Gram-positive and Gram-negative bacteria Simple Viability Determination SYTOX® Green allows quick determination of cell viability when using flow cytometers, fluorescence microscopes, fluorometers, or fluorescence microplate readers. It will not cross intact membranes, ...
Catalog: S7020
Size: 250 µl

LIVE/DEAD® Fixable Blue Dead Cell Stain Kit, for UV excitation

Category: Products & Services > Kits & Assays > Cell Analysis Kits > Cell Viability Kits

The LIVE/DEAD® Fixable Dead Cell Stain Kit employs an amine-reactive fluorescent dye to evaluate mammalian cell viability by flow cytometry. In cells with compromised membranes, the dye reacts with free amines both in the cell interior and on the cell surface, yielding intense fluorescent staining. In viable cells, the dye's reactivity is restricted to the cell-surface amines, resulting in less intense fluorescence. The difference in intensity between the live and dead cell populations is typically greater than 50 fold, and this fluorescence intensity discrimination is completely preserved fol...
Catalog: L-23105
Size: 1 kit

ER-Tracker™ Blue-White DPX, for live-cell imaging

Category: Products & Services > Labeling & Detection Products > Cell Stains > Organelle Stains

ER-Tracker Blue-White DPX dye is a photostable probe that is selective for the endoplasmic reticulum (ER) in live cells. The cells can be aldehyde-fixed after staining with the dye but significant fluorescence signal will be lost. With excitation at ~374 nm, the environmentally-sensitive probe exhibits emission between 430 and 640 nm. A long-pass DAPI filter works best.
Catalog: E-12353
Size: 20 × 50 µl

CellTracker™ Blue CMAC (7-Amino-4-Chloromethylcoumarin)

Category: Products & Services > Labeling & Detection Products > Labels & Labeling Kits > Cell, Tissue, & In Vivo Labeling Reagents

Molecular Probes® CellTracker™ fluorescent probes freely pass through cell membranes and are converted to cell-impermeant reaction products. The cell-impermeant form is passed to daughter cells through several generations but is not transferred to adjacent cells in the population. Cells that are loaded with CellTracker™ probes are typically fluorescent and viable for at least 24 hours, making these probes excellent long-term cell tracers. Furthermore, the staining pattern can be fixed with formaldehyde or glutaraldehyde to allow long-term storage of the labeled cells or tissue, to facilitate s...
Catalog: C2110
Size: 5 mg

Covaris® M220 miniTUBE, Blue

Category: Products & Services > Instruments, Software, & Accessories > Tips, Tubes, Strips & Accessories > Sequencing Tubes & Strips

The Covaris® M220 Blue miniTUBE is specifically engineered to shear genomic DNA into fragment size distributions centered on 3 kb. Fragment distributions are tight and precisely centered on the targeted size. Each blue miniTUBE can process 200 µl of sample. Each package contains 25 tubes.
Catalog: 4482268
Size: 25⁄box

EVOS® Condenser Slider, Blue

Category: Products & Services > Instruments, Software, & Accessories > Imaging & Microscopy Accessories > Imaging System Accessories

Condenser sliders are used to improve illumination under certain conditions and several are available for the EVOS® imaging systems, including a diffuser slider, pinhole slider, and meniscus sliders. Due to variances in sample size, color and thickness, actual slider use may differ from suggestions. This blue slider is intended for brightfield applications at all magnifications as a daylight-correction filter for use with a color camera, like the one included with the EVOS® FL Color Imaging System. The EVOS® XL system enables direct adjustment of the white light LED color temperature. Explore ...
Catalog: AMEPCFB
Size: 1 each

Gel Loading Buffer II (Denaturing PAGE)

Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Nucleic Acid Gel Loading Buffers

A 1–2X solution of 95% Formamide, 18 mM EDTA, and 0.025% SDS, Xylene Cyanol, and Bromophenol Blue. Supplied in one 1.4 mL tube. All Ambion® Gel Loading Solutions are rigorously tested for non-specific endonuclease activity, exonuclease activity, RNase activity, and for functionality. These are the same solutions we use in-house and in our kits.
Catalog: AM8546G
Size: 1 ml

Novex® TBE-Urea Sample Buffer (2X)

Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Nucleic Acid Gel Loading Buffers

Denaturing polyacrylamide TBE-Urea Gels resolve single-stranded DNA oligos or RNA into sharp, distinct bands. Novex® TBE-Urea Gels are optimized for the analysis and purification of products ranging from 20-800 bases, making them an ideal choice for synthetic oligo analysis and purification, RNase Protection Assays (RPA), in vitro transcription studies, and Northern blot analysis. Novex® TBE-Urea Gels are designed to run on the XCell SureLock ™ Mini-Cell. Formulation: Novex® TBE-Urea Gels are made with high-purity reagents, including tris base, boric acid, EDTA, acrylamide, bisacrylamide, TEME...
Catalog: LC6876
Size: 10 ml

Novex® Hi-Density TBE Sample Buffer (5X)

Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Nucleic Acid Gel Loading Buffers

Novex® TBE Gels provide the highest resolution possible for analyzing restriction digests and PCR products. DNA fragments ranging from 10 to 3,000 base pairs are clearly resolved into sharp, tight bands. Novex® DNA Retardation gels are prepared with 0.5X TBE as the gel buffer. This is sufficient for good electrophoretic separation, yet low enough to promote DNA-protein interactions. Novex® TBE and DNA Retardation Gels are designed to run on the XCell SureLock ™ Mini-Cell. Formulation: Novex® TBE and DNA Retardation Gels are manufactured with high-purity tris base, boric acid, EDTA, acrylamide,...
Catalog: LC6678
Size: 10 ml

10X BlueJuice™ Gel Loading Buffer

Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Nucleic Acid Gel Loading Buffers

BlueJuice™ Gel Loading Buffer is designed for easy loading and tracking of DNA samples in agarose or native polyacrylamide gels.
Catalog: 10816-015
Size: 3 × 1 ml

Violet Ratiometric Membrane Asymmetry Probe/Dead Cell Apoptosis Kit, for flow cytometry

Category: Products & Services > Kits & Assays > Cell Analysis Kits > Apoptosis Kits

The Violet Ratiometric Membrane Asymmetry Probe⁄Dead Cell Apoptosis Kit provides a simple and fast method for the detection of apoptosis with dead cell discrimination by flow cytometry. The Violet Ratiometric Membrane Asymmetry Probe, 4'-N,N-diethylamino-6-(N,N,N-dodecyl-methylamino-sulfopropyl)-methyl-3-hydroxyflavone (F2N12S), is a novel violet excitable dye for the detection of membrane asymmetry changes during apoptosis. The dye exhibits an excited-state intramolecular proton transfer (ESIPT) reaction resulting in a dual fluorescence with two emission bands corresponding to 530 nm and 585 ...
Catalog: A-35137
Size: 1 kit