Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers
The NuPAGE® MOPS SDS Running Buffer (20X) is formulated for running proteins on NuPAGE® Novex® Bis-Tris gels. NuPAGE® MOPS SDS Running Buffer is recommended for separating medium- to large-sized proteins. Use the Right Buffer to Optimize Protein Separations NuPAGE® MES SDS Running Buffer and NuPAGE® MOPS SDS Running Buffer can both be used with the NuPAGE® Bis-Tris gels. Using MOPS buffer allows proteins to run slower vs. MES buffer. Get Consistent, Convenient High-Quality Results Pre-mixed NuPAGE® buffers are a convenient way to ensure high-quality, consistent electrophoresis results. All buf...
Catalog: NP0001-02
Size: 5 L
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers
Novex® Tris-Glycine polyacrylamide gel chemistry is based on the Laemmli system (1) with minor modifications for maximum performance in the pre-cast format. These gels do not contain SDS and can therefore be used to accurately separate both native and denatured proteins. Novex® Tris-Glycine Gels provide reproducible separation of a wide range of proteins into well-resolved bands. Formulation: Novex® Tris-Glycine Gels are made with high-purity, strictly quality-controlled reagents: Tris base, HCl, acrylamide, bisacrylamide, TEMED, APS, and highly purified water. They do not contain SDS. Recomme...
Catalog: LC2675-5
Size: 5 L
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers
NuPAGE® MES SDS Running Buffer (20X) is formulated for running proteins on NuPAGE® Novex® Bis-Tris gels. NuPAGE® MES SDS Running Buffer is recommended for separating small- to medium-sized proteins. Use the Right Buffer to Optimize Protein Separations NuPAGE® MES SDS Running Buffer and NuPAGE® MOPS SDS Running Buffer can both be used with the NuPAGE® Bis-Tris gels. Using MES buffer allows proteins to run faster vs. MOPS buffer. Get Consistent, Convenient High-Quality Results Pre-mixed NuPAGE® buffers are a convenient way to ensure high-quality, consistent electrophoresis results. All buffers a...
Catalog: NP0002
Size: 500 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers
NuPAGE® Novex Tris-Acetate Gels provide excellent separation of large molecular weight proteins when used with NuPAGE® Tris-Acetate SDS Running Buffer. NuPAGE® Novex Tris-Acetate gels can also be run with Tris-Glycine Native Running Buffer to resolve native proteins more effectively than the Tris-Glycine gel system. Formulation: NuPAGE® Novex Tris-Acetate gels are made with high-purity, strictly quality-controlled reagents: Tris base, acetic acid, acrylamide, bis-acrylamide, TEMED, APS, and highly purified water. They do not contain SDS. Recommended Buffers: Run NuPAGE® Novex Tris-Acetate gels...
Catalog: LA0041
Size: 500 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers
The NativePAGE™ Running Buffer Kit contains the NativePAGE™ Running Buffer (20X), which is used to make the NativePAGE™ Cathode and Anode Running Buffers for use with an XCell SureLock® Mini Cell when running NativePAGE™ Gels. The kit also contains the NativePAGE™ Cathode Buffer Additive (20X) that is used with the NativePAGE™ Running Buffer to make the Cathode Running Buffer for the system.
Catalog: BN2007
Size: 1 kit
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Sample Buffers
Novex® Tris-Glycine polyacrylamide gel chemistry is based on the Laemmli system (1) with minor modifications for maximum performance in the pre-cast format. These gels do not contain SDS and can therefore be used to accurately separate both native and denatured proteins. Novex® Tris-Glycine Gels provide reproducible separation of a wide range of proteins into well-resolved bands. Formulation: Novex® Tris-Glycine Gels are made with high-purity, strictly quality-controlled reagents: Tris base, HCl, acrylamide, bisacrylamide, TEMED, APS, and highly purified water. They do not contain SDS. Recomme...
Catalog: LC2676
Size: 20 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Nucleic Acid Gel Running Buffers
UltraPure™ DNA Typing Grade® 50X TAE Buffer is a sterile-filtered solution of 2 M Tris-acetate and 50 mM EDTA. TAE Buffer is the most commonly used buffer for agarose DNA electrophoresis. To prepare a 1X solution, mix one volume of UltraPure™ 50X TAE Buffer with 49 volumes of distilled water. A 1X TAE Buffer solution contains 40 mM Tris-acetate and 1 mM EDTA with a pH of 8.3 at 23“C. Performance and Quality Testing: No DNase activity detected.
Catalog: 24710-030
Size: 1 L
Category: Products & Services > Kits & Assays > Nucleic Acid Detection & Analysis Kits > Northern Blotting Kits & Reagents
For the preparation and running of agarose gels. For use with RNA denatured by glyoxal treatment; one bottle containing 1 L is provided. Ambion® NorthernMax® reagents are the same components included in the NorthernMax® Ultrasensitive Northern Blotting Kits but in larger sizes. These reagents are supplied ready to use and are certified RNase-free. Comprehensive instructions are included.
Catalog: AM8678
Size: 1 L
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Sample Buffers
NuPAGE® Novex 3-8% Tris-Acetate Midi-Gels provide excellent separation of large molecular weight proteins when used with NuPAGE® Tris-Acetate SDS Running Buffer. NuPAGE® Novex Tris-Acetate gels can also be run with Tris-Glycine Native Running Buffer to resolve native proteins more effectively than the Tris-Glycine gel system. NuPAGE® Novex Tris-Acetate Midi-Gels (8 x 13 cm) can run up to 26 samples. The NuPAGE Midi-Gels run in the XCell4 Surelock™ Midi-Cell and, with a Midi Gel Adapter, can run in a Bio-Rad Criterion Cell. Formulation: NuPAGE® Novex Tris-Acetate gels are made with high-purity,...
Catalog: LA0050
Size: 1 kit
Category: Products & Services > Buffers & Chemicals > Denaturing Agents
Ambion® molecular biology grade, SDS, 20% Solution is supplied in one bottle containing 250 mL. The buffer is certified RNase-free, economical, and ready-to-use. SDS is used as a component of both hybridization and wash buffers for northern and Southern blots and has many other uses around the lab.
Catalog: AM9820
Size: 250 ml
Category: Products & Services > Buffers & Chemicals > Denaturing Agents
Molecular biology grade, Ambion® SDS, 10% Solution is supplied in one bottle containing 1 L. The buffer is certified RNase-free, economical, and ready-to-use. SDS is used as a component of both hybridization and wash buffers for northern and Southern blots and has many other uses around the lab.
Catalog: AM9823
Size: 1 L
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Nucleic Acid Gel Running Buffers
Molecular biology grade, Ambion® 10X TBE solution is supplied in four bottles containing 1 L each. The buffer is certified RNase-free, economical, and ready-to-use. Due to the ubiquitous presence of RNases, manufacturing products for use with RNA is especially challenging. Ambion®'s nuclease-free reagents and buffers are manufactured in facilities specifically designed to prevent the introduction of nucleases. Highly sensitive RNase assays are performed at several different stages of the manufacturing process to ensure the highest quality. These reagents are rigorously tested for contaminating...
Catalog: AM9865
Size: 4 bottle