Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers
NuPAGE® MOPS SDS Running Buffer (20X) is formulated for running proteins on NuPAGE® Novex® Bis-Tris gels only. NuPAGE® MOPS SDS Running Buffer is recommended for separating small- to medium-sized proteins. Use the right buffer to optimize protein separations NuPAGE® MES SDS Running Buffer and NuPAGE® MOPS SDS Running Buffer can both be used with NuPAGE® Novex® Bis-Tris gels. Use of MOPS buffer allows proteins to run slower than when using MES buffer. Get consistent, convenient, high-quality results Pre-mixed NuPAGE® buffers are a convenient way to ensure high-quality, consistent electrophoresi...
Catalog: NP0001-02
Size: 5 L
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers
Novex® Tris-Glycine SDS Running Buffer (10X) is formulated for separation of proteins, in their denatured state, on Novex® Tris-Glycine gels. Tris-Glycine gels provide reproducible separation of a wide range of proteins into well-resolved bands, depending upon the gel percentage used. Separate native or denatured proteins Novex®Tris-Glycine gels do not contain SDS and can be used to accurately separate both native and denatured proteins, depending upon the sample and running buffers used. To separate denatured proteins on Novex® Tris-Glycine gels, use Novex® Tris-Glycine Native Sample Buffer a...
Catalog: LC2675-5
Size: 5 L
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers
The NativePAGE™ Running Buffer Kit contains the NativePAGE™ Running Buffer (20X), which is used to make the NativePAGE™ Cathode and Anode Running Buffers for use with an XCell SureLock® Mini Cell when running NativePAGE™ Gels. The kit also contains the NativePAGE™ Cathode Buffer Additive (20X) that is used with the NativePAGE™ Running Buffer to make the Cathode Running Buffer for the system.
Catalog: BN2007
Size: 1 kit
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers
NuPAGE® MES SDS Running Buffer (20X) is formulated for running proteins on NuPAGE® Novex® Bis-Tris gels only. NuPAGE® MES SDS Running Buffer is recommended for separating small- to medium-sized proteins. Use the right buffer to optimize protein separations NuPAGE® MES SDS Running Buffer and NuPAGE® MOPS SDS Running Buffer can both be used with NuPAGE® Novex® Bis-Tris gels. Use of MES buffer allows proteins to run faster than when using MOPS buffer. Get consistent, convenient, high-quality results Pre-mixed NuPAGE® buffers are a convenient way to ensure high-quality, consistent electrophoresis ...
Catalog: NP0002
Size: 500 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers
NuPAGE® Tris-Acetate SDS Running Buffer (20X) is formulated for separation of proteins, in their denatured state, on NuPAGE® Novex® Tris-Acetate gels. NuPAGE® Novex® Tris-Acetate gels provide excellent separation of large molecular weight proteins when used with NuPAGE® Tris-Acetate SDS Running Buffer. NuPAGE® Novex® Tris-Acetate gels can also be run with Novex® Tris-Glycine Native Running Buffer to resolve native proteins more effectively than with the Tris-Glycine gel system. Formulation NuPAGE® Novex® Tris-Acetate gels are made with high-purity, strictly quality-controlled reagents: Tris ba...
Catalog: LA0041
Size: 500 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Nucleic Acid Gel Running Buffers
UltraPure™ DNA Typing Grade® 50X TAE Buffer is a sterile-filtered solution of 2 M Tris-acetate and 50 mM EDTA. TAE Buffer is the most commonly used buffer for agarose DNA electrophoresis. To prepare a 1X solution, mix one volume of UltraPure™ 50X TAE Buffer with 49 volumes of distilled water. A 1X TAE Buffer solution contains 40 mM Tris-acetate and 1 mM EDTA with a pH of 8.3 at 23“C. Performance and Quality Testing: No DNase activity detected.
Catalog: 24710-030
Size: 1 L
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Sample Buffers
NuPAGE® Novex 3-8% Tris-Acetate Midi-Gels provide excellent separation of large molecular weight proteins when used with NuPAGE® Tris-Acetate SDS Running Buffer. NuPAGE® Novex Tris-Acetate gels can also be run with Tris-Glycine Native Running Buffer to resolve native proteins more effectively than the Tris-Glycine gel system. NuPAGE® Novex Tris-Acetate Midi-Gels (8 x 13 cm) can run up to 26 samples. The NuPAGE Midi-Gels run in the XCell4 Surelock™ Midi-Cell and, with a Midi Gel Adapter, can run in a Bio-Rad Criterion Cell. Formulation: NuPAGE® Novex Tris-Acetate gels are made with high-purity,...
Catalog: LA0050
Size: 1 kit
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Transfer Buffers
NuPAGE® Transfer Buffer (20X) is a buffer used to transfer proteins from NuPAGE® Novex® gels to membranes for Western blotting. NuPAGE® Transfer Buffer can be used with the Novex® Semi-Dry Blotter for semi-dry transfer or with the XCell II™ Blot Module for wet (tank) transfer. NuPAGE® Antioxidant may be used with NuPAGE® Transfer Buffer to enhance transfer of reduced proteins to membranes. Related link Learn more about other Invitrogen™ products for your protein transfer needs .
Catalog: NP0006-1
Size: 1 L
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Sample Buffers
NuPAGE® LDS Sample Buffer (4X) is used to prepare protein samples for denaturing gel electrophoresis with NuPAGE® Novex® gels. Optimal protein sample preparation for polyacrylamide gel electrophoresis (PAGE) requires denaturing and reducing protein disulfide bonds. NuPAGE® LDS Sample Buffer contains lithium dodecyl sulfate, pH 8.4, which allows for maximum activity of the reducing agent. For native gel electrophoresis, use Novex® Tris-Glycine Native Sample Buffer (2X) . Note: NuPAGE® LDS Sample Buffer should be brought to room temperature (25°C) prior to use. NuPAGE® LDS Sample Buffer is a hig...
Catalog: NP0007
Size: 10 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Sample Buffers
NuPAGE® LDS Sample Buffer (4X) (250 ml) is used to prepare protein samples for denaturing gel electrophoresis with the NuPAGE® gels. Optimal protein sample preparation for polyacrylamide gel electrophoresis (PAGE) requires denaturing and reducing the protein disulfide bonds. NuPAGE® LDS Sample Buffer contains lithium dodecyl sulfate at a pH of 8.4, which allows for maximal activity of the reducing agent. For native gel electrophoresis, use Novex® Tris-Glycine Native Sample Buffer (2X) . Note: NuPAGE® LDS Sample Buffer should be brought to room temperature (25°C) prior to use. NuPAGE® LDS Sampl...
Catalog: NP0008
Size: 250 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Transfer Buffers
Bolt® Transfer Buffer is optimized for the transfer of proteins from Bolt® Bis-Tris Plus gels to membranes for western blotting. When combined with 10% methanol, Bolt® Transfer Buffer can be used with the Bolt® Mini Blot Module for wet transfer. Bolt® Transfer Buffer can also be used with Bolt® Antioxidant to enhance transfer of reduced proteins to membranes. About the Bolt® Mini Blot Module The Bolt® Mini Blot Module is a wet transfer device used exclusively with the Bolt® Mini Gel Tank. The tank accommodates one blot module per chamber, or two blot modules total with the side-by-side layout....
Catalog: BT00061
Size: 1 L
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Transfer Buffers
NuPAGE® Transfer Buffer (20X) is a buffer used to transfer proteins from NuPAGE® Novex® gels to membranes for Western blotting. NuPAGE® Transfer Buffer can be used with the Novex® Semi-Dry Blotter for semi-dry transfer or with the XCell II™ Blot Module for wet (tank) transfer. NuPAGE® Antioxidant may be used with NuPAGE® Transfer Buffer to enhance transfer of reduced proteins to membranes. Related link Learn more about other Invitrogen™ products for your protein transfer needs .
Catalog: NP0006
Size: 125 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Sample Buffers
Novex® Tris-Glycine polyacrylamide gel chemistry is based on the Laemmli system (1) with minor modifications for maximum performance in the pre-cast format. These gels do not contain SDS and can therefore be used to accurately separate both native and denatured proteins. Novex® Tris-Glycine Gels provide reproducible separation of a wide range of proteins into well-resolved bands. Formulation: Novex® Tris-Glycine Gels are made with high-purity, strictly quality-controlled reagents: Tris base, HCl, acrylamide, bisacrylamide, TEMED, APS, and highly purified water. They do not contain SDS. Recomme...
Catalog: LC2676
Size: 20 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Transfer Buffers
Novex® Tris-Glycine Transfer Buffer (25X) is specially optimized for western blot transfer applications using Tris-Glycine gels.
Catalog: LC3675
Size: 500 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Transfer Buffers
Bolt® Transfer Buffer is optimized for the transfer of proteins from Bolt® Bis-Tris Plus gels to membranes for western blotting. When combined with 10% methanol, Bolt® Transfer Buffer can be used with the Bolt® Mini Blot Module for wet transfer. Bolt® Transfer Buffer can also be used with Bolt® Antioxidant to enhance transfer of reduced proteins to membranes. About the Bolt® Mini Blot Module The Bolt® Mini Blot Module is a wet transfer device used exclusively with the Bolt® Mini Gel Tank. The tank accommodates one blot module per chamber, or two blot modules total with the side-by-side layout....
Catalog: BT0006
Size: 125 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Nucleic Acid Gel Running Buffers
Molecular biology grade, Ambion® 10X TBE solution is supplied in four bottles containing 1 L each. The buffer is certified RNase-free, economical, and ready-to-use. Due to the ubiquitous presence of RNases, manufacturing products for use with RNA is especially challenging. Ambion®'s nuclease-free reagents and buffers are manufactured in facilities specifically designed to prevent the introduction of nucleases. Highly sensitive RNase assays are performed at several different stages of the manufacturing process to ensure the highest quality. These reagents are rigorously tested for contaminating...
Catalog: AM9865
Size: 4 bottle
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Sample Buffers
NativePAGE™ 5% G-250 Sample Additive is added to samples prepared with the NativePAGE™ Sample Buffer and detergents (10% DMM or 5% Digitonin) just prior to applying the samples to NativePAGE™ gels. This Additive is also included in the NativePAGE™ Sample Prep Kit. The samples prepared with 10% DDM, 5% Digitonin, or the NativePAGE™ Sample Prep Kit are compatible with NativePAGE™ Novex Bis-Tris Gels for native electrophoresis showing increased resolution and reduced streaking.
Catalog: BN2004
Size: 0.5 ml
Category: Products & Services > Kits & Assays > Nucleic Acid Detection & Analysis Kits > Northern Blotting Kits & Reagents
For the preparation and running of agarose gels. For use with RNA denatured by glyoxal treatment; one bottle containing 1 L is provided. Ambion® NorthernMax® reagents are the same components included in the NorthernMax® Ultrasensitive Northern Blotting Kits but in larger sizes. These reagents are supplied ready to use and are certified RNase-free. Comprehensive instructions are included.
Catalog: AM8678
Size: 1 L