Category: Products & Services > Instruments, Software, & Accessories > Gel Boxes, Gel Imagers, Power Supplies & Accessories > Gel Imagers & Digital Electrophoresis Systems
The E-Gel® Camera Hood Kit, when combined with a base, forms the E-Gel® Imager System, which is a personal imaging system for documenting and analyzing agarose gels and E-Gel® cassettes. Each E-Gel® Camera Hood Kit includes a compact digital camera mounted in a sleek hood, a universal filter, power and USB cables, and two powerful software applications. There are three bases available for purchase that will work with the E-Gel® Camera Hood Kit: a UV Light Base, a Blue Light Base, and an E-Gel® Adaptor Base. In any of these three configurations, the E-Gel® Imager system provides a small and lig...
Catalog: 4466601
Size: 1 kit
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Agarose
UltraPure™ Agarose is a polysaccharide (see structure below) used for size-based separation of nucleic acids in agarose gel electrophoresis applications. UltraPure™ Agarose is ideal for resolving DNA and RNA fragments from 500 bp to > 20 kb. • Ideal for analysis and recovery of DNA and RNA for routine applications • Strong gel structure allows for better handling and less breakage • Can be used in protein electrophoresis applications such as Ouchterlony (antigen-antibody interaction assay) and radial immunodiffusion (RID) (antigen quantitation assay) Improved Packaging The new environmentally ...
Catalog: 16500100
Size: 100 g
Category: Products & Services > Instruments, Software, & Accessories > Gel Boxes, Gel Imagers, Power Supplies & Accessories > Other Gel Electrophoresis Accessories
Replacement Parts for Electrophoresis Apparatus
Catalog: EI0012
Size: each
Category: Products & Services > Instruments, Software, & Accessories > Gel Boxes, Gel Imagers, Power Supplies & Accessories > Other Gel Electrophoresis Accessories
Novex® Midi Empty Cassette Combs are designed to be used when pouring your own gels using Novex® Midi Empty Cassettes. Each comb has 20 wells and is 1 mm thick. For Research Use Only. Not intended for animal or human diagnostic or therapeutic use.
Catalog: WC1020
Size: 1 pack
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Nucleic Acid Gel Loading Buffers
The TrackIt™ Loading Buffers are a 6X solution used for easy loading and tracking of DNA samples in agarose gels. These loading buffers contain two tracking dyes, one that runs behind the sample and one that runs ahead of the sample. The tracking dyes serve as visual markers for following migration during electrophoresis and indicate when maximum resolution of the DNA fragments has been achieved. Additionally, visualization of DNA bands will not be obscured by the tracking dyes because they run outside the limits of most DNA samples. TrackIt™ Cyan/Orange Loading Buffer is recommended for DNA f...
Catalog: 10482-028
Size: 3 × 0.5 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Sample Buffers
Novex® Tris-Glycine polyacrylamide gel chemistry is based on the Laemmli system (1) with minor modifications for maximum performance in the pre-cast format. These gels do not contain SDS and can therefore be used to accurately separate both native and denatured proteins. Novex® Tris-Glycine Gels provide reproducible separation of a wide range of proteins into well-resolved bands. Formulation: Novex® Tris-Glycine Gels are made with high-purity, strictly quality-controlled reagents: Tris base, HCl, acrylamide, bisacrylamide, TEMED, APS, and highly purified water. They do not contain SDS. Recomme...
Catalog: LC2676
Size: 20 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Transfer Buffers
Novex® Tris-Glycine Transfer Buffer (25X) is specially optimized for western blot transfer applications using Tris-Glycine gels.
Catalog: LC3675
Size: 500 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers
NuPAGE® Novex Tris-Acetate Gels provide excellent separation of large molecular weight proteins when used with NuPAGE® Tris-Acetate SDS Running Buffer. NuPAGE® Novex Tris-Acetate gels can also be run with Tris-Glycine Native Running Buffer to resolve native proteins more effectively than the Tris-Glycine gel system. Formulation: NuPAGE® Novex Tris-Acetate gels are made with high-purity, strictly quality-controlled reagents: Tris base, acetic acid, acrylamide, bis-acrylamide, TEMED, APS, and highly purified water. They do not contain SDS. Recommended Buffers: Run NuPAGE® Novex Tris-Acetate gels...
Catalog: LA0041
Size: 500 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers
Novex® Tris-Glycine polyacrylamide gel chemistry is based on the Laemmli system (1) with minor modifications for maximum performance in the pre-cast format. These gels do not contain SDS and can therefore be used to accurately separate both native and denatured proteins. Novex® Tris-Glycine Gels provide reproducible separation of a wide range of proteins into well-resolved bands. Formulation: Novex® Tris-Glycine Gels are made with high-purity, strictly quality-controlled reagents: Tris base, HCl, acrylamide, bisacrylamide, TEMED, APS, and highly purified water. They do not contain SDS. Recomme...
Catalog: LC2675-5
Size: 5 L
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Sample Buffers
NuPAGE® LDS Sample Buffer (4X) (10 ml) is used to prepare protein samples for denaturing gel electrophoresis with the NuPAGE® gels. Optimal protein sample preparation for polyacrylamide gel electrophoresis (PAGE) requires denaturing and reducing the protein disulfide bonds. NuPAGE® LDS Sample Buffer contains lithium dodecyl sulfate at a pH of 8.4, which allows for maximal activity of the reducing agent. For native gel electrophoresis, use Novex® Tris-Glycine Native Sample Buffer (2X) . Note: NuPAGE® LDS Sample Buffer should be brought to room temperature (25°C) prior to use. NuPAGE® LDS Sample...
Catalog: NP0007
Size: 10 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Sample Buffers
NativePAGE™ 5% G-250 Sample Additive is added to samples prepared with the NativePAGE™ Sample Buffer and detergents (10% DMM or 5% Digitonin) just prior to applying the samples to NativePAGE™ gels. This Additive is also included in the NativePAGE™ Sample Prep Kit. The samples prepared with 10% DDM, 5% Digitonin, or the NativePAGE™ Sample Prep Kit are compatible with NativePAGE™ Novex Bis-Tris Gels for native electrophoresis showing increased resolution and reduced streaking.
Catalog: BN2004
Size: 0.5 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Sample Buffers
NuPAGE® LDS Sample Buffer (4X) (250 ml) is used to prepare protein samples for denaturing gel electrophoresis with the NuPAGE® gels. Optimal protein sample preparation for polyacrylamide gel electrophoresis (PAGE) requires denaturing and reducing the protein disulfide bonds. NuPAGE® LDS Sample Buffer contains lithium dodecyl sulfate at a pH of 8.4, which allows for maximal activity of the reducing agent. For native gel electrophoresis, use Novex® Tris-Glycine Native Sample Buffer (2X) . Note: NuPAGE® LDS Sample Buffer should be brought to room temperature (25°C) prior to use. NuPAGE® LDS Sampl...
Catalog: NP0008
Size: 250 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Transfer Buffers
Bolt® Transfer Buffer is optimized for the transfer of proteins from Bolt® Bis-Tris Plus gels to membranes for western blotting. When combined with 10% methanol, Bolt® Transfer Buffer can be used with the Bolt® Mini Blot Module for wet transfer. Bolt® Transfer Buffer can also be used with Bolt® Antioxidant to enhance transfer of reduced proteins to membranes. About the Bolt® Mini Blot Module The Bolt® Mini Blot Module is a wet transfer device used exclusively with the Bolt® Mini Gel Tank. The tank accommodates one blot module per chamber, or two blot modules total with the side-by-side layout....
Catalog: BT0006
Size: 125 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Transfer Buffers
Bolt® Transfer Buffer is optimized for the transfer of proteins from Bolt® Bis-Tris Plus gels to membranes for western blotting. When combined with 10% methanol, Bolt® Transfer Buffer can be used with the Bolt® Mini Blot Module for wet transfer. Bolt® Transfer Buffer can also be used with Bolt® Antioxidant to enhance transfer of reduced proteins to membranes. About the Bolt® Mini Blot Module The Bolt® Mini Blot Module is a wet transfer device used exclusively with the Bolt® Mini Gel Tank. The tank accommodates one blot module per chamber, or two blot modules total with the side-by-side layout....
Catalog: BT00061
Size: 1 L