For Gel

OWL Centipede™ Gel System

Category: Products & Services > Instruments, Software, & Accessories > Gel Boxes, Gel Imagers, Power Supplies & Accessories > Gel Boxes

• For use with SSP products or any application requiring agarose gel separation • Multiple formats available to meet various throughput needs • Includes replacement parts for each unit
Catalog: 80000-1D
Size: 1 each

E-Gel® Imager Camera Hood Kit

Category: Products & Services > Instruments, Software, & Accessories > Gel Boxes, Gel Imagers, Power Supplies & Accessories > Gel Imagers & Digital Electrophoresis Systems

The E-Gel® Camera Hood Kit, when combined with a base, forms the E-Gel® Imager System, which is a personal imaging system for documenting and analyzing agarose gels and E-Gel® cassettes. Each E-Gel® Camera Hood Kit includes a compact digital camera mounted in a sleek hood, a universal filter, power and USB cables, and two powerful software applications. There are three bases available for purchase that will work with the E-Gel® Camera Hood Kit: a UV Light Base, a Blue Light Base, and an E-Gel® Adaptor Base. In any of these three configurations, the E-Gel® Imager system provides a small and lig...
Catalog: 4466601
Size: 1 kit

NuPAGE® Novex® 3-8% Tris-Acetate Gel 1.5 mm, 15 Well

Category: Products & Services > Gels, Fractionation Strips, & Membranes > Pre-Cast Protein Gels > Tris-Acetate Gels

NuPAGE® Novex Tris-Acetate Gels provide excellent separation of large molecular weight proteins when used with NuPAGE® Tris-Acetate SDS Running Buffer. NuPAGE® Novex Tris-Acetate gels can also be run with Tris-Glycine Native Running Buffer to resolve native proteins more effectively than the Tris-Glycine gel system. Formulation: NuPAGE® Novex Tris-Acetate gels are made with high-purity, strictly quality-controlled reagents: Tris base, acetic acid, acrylamide, bis-acrylamide, TEMED, APS, and highly purified water. They do not contain SDS. Recommended Buffers: Run NuPAGE® Novex Tris-Acetate gels...
Catalog: EA03785BOX
Size: 1 box

NuPAGE® Novex® 3-8% Tris-Acetate Gel 1.0 mm, 2D Well

Category: Products & Services > Gels, Fractionation Strips, & Membranes > Pre-Cast Protein Gels > 2-D Gels

NuPAGE® Novex Tris-Acetate Gels provide excellent separation of large molecular weight proteins when used with NuPAGE® Tris-Acetate SDS Running Buffer. NuPAGE® Novex Tris-Acetate gels can also be run with Tris-Glycine Native Running Buffer to resolve native proteins more effectively than the Tris-Glycine gel system. Formulation: NuPAGE® Novex Tris-Acetate gels are made with high-purity, strictly quality-controlled reagents: Tris base, acetic acid, acrylamide, bis-acrylamide, TEMED, APS, and highly purified water. They do not contain SDS. Recommended Buffers: Run NuPAGE® Novex Tris-Acetate gels...
Catalog: EA0376BOX
Size: 1 box

Midi-Gel Adapters

Category: Products & Services > Instruments, Software, & Accessories > Gel Boxes, Gel Imagers, Power Supplies & Accessories > Other Gel Electrophoresis Accessories

The Midi Gel Adapter is designed for use with the Novex® Midi Gel Cassette (NuPAGE® or Tris-Glycine Gels) to perform electrophoresis using a BioRad Criterion™ Cell. The Midi Gel Adapter is also supplied with the Novex® Midi Gels with Adapters Kit.
Catalog: WA0999
Size: 10⁄box

NuPAGE® Novex® 7% Tris-Acetate Gel 1.0 mm, 12 Well

Category: Products & Services > Gels, Fractionation Strips, & Membranes > Pre-Cast Protein Gels > Tris-Acetate Gels

NuPAGE® Novex Tris-Acetate Gels provide excellent separation of large molecular weight proteins when used with NuPAGE® Tris-Acetate SDS Running Buffer. NuPAGE® Novex Tris-Acetate gels can also be run with Tris-Glycine Native Running Buffer to resolve native proteins more effectively than the Tris-Glycine gel system. Formulation: NuPAGE® Novex Tris-Acetate gels are made with high-purity, strictly quality-controlled reagents: Tris base, acetic acid, acrylamide, bis-acrylamide, TEMED, APS, and highly purified water. They do not contain SDS. Recommended Buffers: Run NuPAGE® Novex Tris-Acetate gels...
Catalog: EA03552BOX
Size: 1 box

8% TBE Gels 1.0 mm, 10 Well

Category: Products & Services > Gels, Fractionation Strips, & Membranes > Pre-Cast Nucleic Acid Gels > Polyacrylamide Gels

Novex® TBE Gels provide the highest resolution possible for analyzing restriction digests and PCR products. DNA fragments ranging from 10 to 3,000 base pairs are clearly resolved into sharp, tight bands. Novex® DNA Retardation gels are prepared with 0.5X TBE as the gel buffer. This is sufficient for good electrophoretic separation, yet low enough to promote DNA-protein interactions. Novex® TBE and DNA Retardation Gels are designed to run on the XCell SureLock ™ Mini-Cell. Formulation: Novex® TBE and DNA Retardation Gels are manufactured with high-purity tris base, boric acid, EDTA, acrylamide,...
Catalog: EC6215BOX
Size: 1 box

6% TBE-Urea Gels 1.0 mm, 10 Well

Category: Products & Services > Gels, Fractionation Strips, & Membranes > Pre-Cast Nucleic Acid Gels > Polyacrylamide Gels

Denaturing polyacrylamide TBE-Urea Gels resolve single-stranded DNA oligos or RNA into sharp, distinct bands. Novex® TBE-Urea Gels are optimized for the analysis and purification of products ranging from 20-800 bases, making them an ideal choice for synthetic oligo analysis and purification, RNase Protection Assays (RPA), in vitro transcription studies, and Northern blot analysis. Novex® TBE-Urea Gels are designed to run on the XCell SureLock ™ Mini-Cell. Formulation: Novex® TBE-Urea Gels are made with high-purity reagents, including tris base, boric acid, EDTA, acrylamide, bisacrylamide, TEME...
Catalog: EC6865BOX
Size: 1 box

6% DNA Retardation Gel 1.0 mm, 10 Well

Category: Products & Services > Gels, Fractionation Strips, & Membranes > Pre-Cast Nucleic Acid Gels > Polyacrylamide Gels

Novex® TBE Gels provide the highest resolution possible for analyzing restriction digests and PCR products. DNA fragments ranging from 10 to 3,000 base pairs are clearly resolved into sharp, tight bands. Novex® DNA Retardation gels are prepared with 0.5X TBE as the gel buffer. This is sufficient for good electrophoretic separation, yet low enough to promote DNA-protein interactions. Novex® TBE and DNA Retardation Gels are designed to run on the XCell SureLock ™ Mini-Cell. Formulation: Novex® TBE and DNA Retardation Gels are manufactured with high-purity tris base, boric acid, EDTA, acrylamide,...
Catalog: EC6365BOX
Size: 1 box

Bolt® Mini Gel Tank

Category: Products & Services > Instruments, Software, & Accessories > Gel Boxes, Gel Imagers, Power Supplies & Accessories > Gel Boxes

The Bolt® Mini Gel Tank is compatible with Bolt® Bis-Tris Plus gels, and can accommodate up to two gels per run. The unique tank design enables convenient side-by-side gel loading and enhanced viewing during use. Optimized conditions using constant voltage allow for Bolt® Bis-Tris Plus gels to be run in approximately 35 minutes. Run times may vary depending on buffer conditions and power supplies being used. Each Bolt® Mini Gel Tank includes: • Gel Runner Tank • Bolt® Tank Base • Bolt® Tank Lid • Cassette Clamps, Right and Left • Novex® Power Supply Adapters • Gel Knife About Bolt® Bis-Tris Pl...
Catalog: B4477599
Size: 1 unit

NuPAGE® Novex® 4-12% Bis-Tris ZOOM® Gels, IPG Well 1.0 mm, IPG Well

Category: Products & Services > Gels, Fractionation Strips, & Membranes > Pre-Cast Protein Gels > 2-D Gels

NuPAGE® Novex Bis-Tris Gels provide the best separation and resolution of small- to medium-sized proteins by utilizing a neutral pH environment which minimizes protein modifications. These high-performance gels have a one-year shelf life when stored at +4°C to 25°C, eliminating the waste of throwing out expired gels. Use NuPAGE® Novex Bis-Tris Gels for protein sequencing, mass spectrometry, and any other techniques where protein integrity is crucial. The NuPAGE® System also provides the most efficient means for transferring proteins to membranes for subsequent analysis. Formulation: The NuPAGE...
Catalog: NP0330BOX
Size: 1 box

6% TBE Gels 1.0 mm, 15 Well

Category: Products & Services > Gels, Fractionation Strips, & Membranes > Pre-Cast Nucleic Acid Gels > Polyacrylamide Gels

Novex® TBE Gels provide the highest resolution possible for analyzing restriction digests and PCR products. DNA fragments ranging from 10 to 3,000 base pairs are clearly resolved into sharp, tight bands. Novex® DNA Retardation gels are prepared with 0.5X TBE as the gel buffer. This is sufficient for good electrophoretic separation, yet low enough to promote DNA-protein interactions. Novex® TBE and DNA Retardation Gels are designed to run on the XCell SureLock ™ Mini-Cell. Formulation: Novex® TBE and DNA Retardation Gels are manufactured with high-purity tris base, boric acid, EDTA, acrylamide,...
Catalog: EC62655BOX
Size: 1 box

NativePAGE™ Novex® 4-16% Bis-Tris Gels 1.0 mm, 15 Well

Category: Products & Services > Gels, Fractionation Strips, & Membranes > Pre-Cast Protein Gels > Bis-Tris Gels

The NativePAGE™ Novex® Bis-Tris Gel System is a pre-cast polyacrylamide mini gel system that provides a sensitive and high-resolution method for analysis of native membrane protein complexes, native soluble proteins, molecular mass estimations, and assessment of purity of native proteins. It is based on the blue native polyacrylamide gel electrophoresis technique (BN PAGE) developed by Schagger and von Jagow (1-3). With the NativePAGE™ Novex® Bis-Tris Gel System, youll: • Simplify resolution of large proteins (15-10,000 kDa) • Analyze membrane-protein complexes in their native conformations • ...
Catalog: BN1004BOX
Size: 1 box

E-Gel® Safe Imager™ Real-Time Transilluminator

Category: Products & Services > Instruments, Software, & Accessories > Gel Boxes, Gel Imagers, Power Supplies & Accessories > Gel Imagers & Digital Electrophoresis Systems

The E-Gel® Safe Imager™ Real-Time Transilluminator allows you to watch migration of DNA in real-time in E-Gels containing SYBR® Safe. It offers: • Real-Time monitoring of DNA migration • Improved safety for the user • Enhanced cloning efficiency of retrieved DNA Real-Time Transilluminator Designed for Safety and Cloning The E-Gel® Safe Imager™ Real-Time Transilluminator is designed to fit perfectly beneath the E-Gel® iBase™ Power System and is intended for use with E-Gels containing SYBR® Safe. Blue light emitted by the instrument is ideal for viewing DNA that is stained with SYBR® Safe. Unlik...
Catalog: G6500
Size: 1 each

Novex® 8% Tris-Glycine Midi Gels 12+2 Well

Category: Products & Services > Gels, Fractionation Strips, & Membranes > Pre-Cast Protein Gels > Tris-Glycine Gels

Novex® 8% Tris-Glycine Midi Gels (12+2 well) are polyacrylamide gels based on traditional Laemmli protein electrophoresis. Novex® Tris-Glycine Gels provide reproducible separation of a wide range of proteins into well-resolved bands. Each box contains 10 gels. • Individually packaged gels for optimal experiment design • Compatible with most protein standards • Usable for native and denaturing protein assays Choose the Right Gel Format for Your Experiments Novex® Tris-Glycine gels come in a variety of fixed concentrations from 4% to 18%, as well as gradients with ranges of 4–12%, 4–20%, 8–16%, ...
Catalog: WT0081BOX
Size: 1 box

NuPAGE® Novex® 4-12% Bis-Tris Gel 1.0 mm, 17 Well

Category: Products & Services > Gels, Fractionation Strips, & Membranes > Pre-Cast Protein Gels > Bis-Tris Gels

NuPAGE® Novex® 4-12% Bis-Tris Gels (1.0-mm thick, 17-well) are pre-cast polyacrylamide gels designed to give optimal separation of your small- to medium-sized proteins under denaturing conditions. Unlike traditional tris-glycine gels, NuPAGE® Novex® Bis-Tris gels have a neutral pH environment that minimizes protein modifications. Use the NuPAGE® Novex Bis-Tris Gels for preparing proteins for sequencing, mass spectrometry, and any other techniques where protein integrity is crucial. Also use NuPAGE® gels to get optimal results for your day-to-day use. NuPAGE® Novex® Bis-Tris Gels come in two si...
Catalog: NP0329BOX
Size: 10 gels⁄box

NuPAGE® MOPS SDS Running Buffer (for Bis-Tris Gels only) (20X) (5 L)

Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers

The NuPAGE® MOPS SDS Running Buffer (20X) is formulated for running proteins on NuPAGE® Novex® Bis-Tris gels. NuPAGE® MOPS SDS Running Buffer is recommended for separating medium- to large-sized proteins. Use the Right Buffer to Optimize Protein Separations NuPAGE® MES SDS Running Buffer and NuPAGE® MOPS SDS Running Buffer can both be used with the NuPAGE® Bis-Tris gels. Using MOPS buffer allows proteins to run slower vs. MES buffer. Get Consistent, Convenient High-Quality Results Pre-mixed NuPAGE® buffers are a convenient way to ensure high-quality, consistent electrophoresis results. All buf...
Catalog: NP0001-02
Size: 5 L

iBlot® Gel Transfer Device

Category: Products & Services > Instruments, Software, & Accessories > Gel Boxes, Gel Imagers, Power Supplies & Accessories > Blotting Systems

The iBlot® Gel Transfer Device performs western blotting transfer efficiently and reliably typically in 7 minutes or less without the need for liquid buffers. The device is integral part of the iBlot® Western Blotting System. The system consists of the device and disposable blotting stacks that contain the buffers and the transfer membrane (nitrocellulose or PVDF), and offers high quality transfer, convenience and speed. The device and the stacks are sold separately. The iBlot® system is ideal for scientists analyzing proteins through western blotting who want: • Complete protein transfer in s...
Catalog: IB1001
Size: 1 each

NuPAGE® Tris-Acetate SDS Buffer Kit (for Tris-Acetate Gels), Contains 1 ea. LA0041, NP0004, NP0005, NP0007

Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Sample Buffers

NuPAGE® Novex 3-8% Tris-Acetate Midi-Gels provide excellent separation of large molecular weight proteins when used with NuPAGE® Tris-Acetate SDS Running Buffer. NuPAGE® Novex Tris-Acetate gels can also be run with Tris-Glycine Native Running Buffer to resolve native proteins more effectively than the Tris-Glycine gel system. NuPAGE® Novex Tris-Acetate Midi-Gels (8 x 13 cm) can run up to 26 samples. The NuPAGE Midi-Gels run in the XCell4 Surelock™ Midi-Cell and, with a Midi Gel Adapter, can run in a Bio-Rad Criterion Cell. Formulation: NuPAGE® Novex Tris-Acetate gels are made with high-purity,...
Catalog: LA0050
Size: 1 kit

NuPAGE® MES SDS Running Buffer (for Bis-Tris Gels only) (20X) (500 ml)

Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers

NuPAGE® MES SDS Running Buffer (20X) is formulated for running proteins on NuPAGE® Novex® Bis-Tris gels. NuPAGE® MES SDS Running Buffer is recommended for separating small- to medium-sized proteins. Use the Right Buffer to Optimize Protein Separations NuPAGE® MES SDS Running Buffer and NuPAGE® MOPS SDS Running Buffer can both be used with the NuPAGE® Bis-Tris gels. Using MES buffer allows proteins to run faster vs. MOPS buffer. Get Consistent, Convenient High-Quality Results Pre-mixed NuPAGE® buffers are a convenient way to ensure high-quality, consistent electrophoresis results. All buffers a...
Catalog: NP0002
Size: 500 ml