Category: Products & Services > Labeling & Detection Products > Cell Stains > Organelle Stains
LysoSensor™ Yellow/Blue DND-160 is a ratiometric probe that can be used to measure the pH of acidic organelles, such as lysosomes. The LysoSensor dye produces blue fluorescence in neutral environments, but changes to yellow fluorescence in more acidic environments. The pK a of LysoSensor Yellow/Blue DND-160 is ~4.2.
Catalog: L-7545
Size: 20 × 50 µl
Category: Products & Services > Labeling & Detection Products > Cell Stains > Organelle Stains
ER-Tracker Blue-White DPX dye is a photostable probe that is selective for the endoplasmic reticulum (ER) in live cells. The cells can be aldehyde-fixed after staining with the dye but significant fluorescence signal will be lost. With excitation at ~374 nm, the environmentally-sensitive probe exhibits emission between 430 and 640 nm. A long-pass DAPI filter works best.
Catalog: E-12353
Size: 20 × 50 µl
Category: Products & Services > Labeling & Detection Products > Cell Stains > Nucleic Acid Cell Stains
The cell-permeant SYTO 60 red fluorescent nucleic acid stain exhibits bright, red fluorescence upon binding to nucleic acids. Because the staining pattern of the SYTO dyes in live cells may vary between cell types, we offer the SYTO Red Fluorescent Nucleic Acid Stain Sampler Kit (S-11340) to enable researchers to find the most appropriate red-fluorescent SYTO stain for their system.
Catalog: S11342
Size: 250 µl
Category: Products & Services > Labeling & Detection Products > Cell Stains > Nucleic Acid Cell Stains
The cell-permeant SYTO 82 orange fluorescent nucleic acid stain exhibits bright, orange fluorescence upon binding to nucleic acids. Because the staining pattern of the SYTO dyes in live cells may vary between cell types, we offer the SYTO Orange Fluorescent Nucleic Acid Stain Sampler Kit (S-11360) to enable researchers to find the most appropriate orange-fluorescent SYTO stain for their system.
Catalog: S11363
Size: 250 µl
Category: Products & Services > Antibodies & Secondary Detection Reagents > Primary Antibodies > Protein Specific Primary Antibodies
The F4/80, clone BM8, Pacific Blue™ dye conjugate is a monoclonal rat antibody that is specific to mouse F4/80 and recognizes the expressed product of the Emr1 gene. Our Pacific Blue™ dye is optimally excited by the violet laser and conjugates of this dye are strongly fluorescent even at neutral pH. Pacific Blue™ and Pacific Orange™ dye conjugates can be simultaneously excited at 405 nm and emit at 455 nm and 551 nm, respectively, facilitating two-color analysis. Antibody Specifications Description: F4/80, Rat IgG2a monoclonal Label: Pacific Blue™ dye Validated Application: Flow Cytometry Spec...
Catalog: MF48028
Size: 1 ml
Category: Products & Services > Antibodies & Secondary Detection Reagents > Avidin, Streptavidin & Biotin > Streptavidin
Our streptavidin, Marina Blue™ conjugate is a bright, blue-fluorescent probe with excitation/emission ~365/460 nm. Streptavidin is a nonglycosylated biotin-binding protein that is isolated from bacteria and has a near-neutral isoelectric point. It is widely used to detect biotinylated probes, because it reportedly exhibits less nonspecific binding than does the glycosylated, biotin-binding protein, avidin.
Catalog: S-11221
Size: 1 mg
Category: Products & Services > Labeling & Detection Products > Cell Stains > Other Cell Stains
Trypan blue stain is a well-accepted method for staining dead cells. It can enter into cells with compromised membranes and is the method used with the Countess® automated cell counting platform.
Catalog: T10282
Size: 2 × 1 ml
Category: Products & Services > Kits & Assays > Cell Analysis Kits > Cell Viability Kits
The LIVE/DEAD® Fixable Dead Cell Stain Kit employs an amine-reactive fluorescent dye to evaluate mammalian cell viability by flow cytometry. In cells with compromised membranes, the dye reacts with free amines both in the cell interior and on the cell surface, yielding intense fluorescent staining. In viable cells, the dye's reactivity is restricted to the cell-surface amines, resulting in less intense fluorescence. The difference in intensity between the live and dead cell populations is typically greater than 50 fold, and this fluorescence intensity discrimination is completely preserved fol...
Catalog: L-23105
Size: 1 kit
Category: Products & Services > Instruments, Software, & Accessories > Tips, Tubes, Strips & Accessories > Sequencing Tubes & Strips
The Covaris® M220 Blue miniTUBE is specifically engineered to shear genomic DNA into fragment size distributions centered on 3 kb. Fragment distributions are tight and precisely centered on the targeted size. Each blue miniTUBE can process 200 µl of sample. Each package contains 25 tubes.
Catalog: 4482268
Size: 25⁄box
Category: Products & Services > Instruments, Software, & Accessories > Imaging & Microscopy Accessories > Imaging System Accessories
Condenser sliders are used to improve illumination under certain conditions and several are available for the EVOS® imaging systems, including a diffuser slider, pinhole slider, and meniscus sliders. Due to variances in sample size, color and thickness, actual slider use may differ from suggestions. This blue slider is intended for brightfield applications at all magnifications as a daylight-correction filter for use with a color camera, like the one included with the EVOS® FL Color Imaging System. The EVOS® XL system enables direct adjustment of the white light LED color temperature. Explore ...
Catalog: AMEPCFB
Size: 1 each
Category: Products & Services > Oligos, Primers, Probes & Nucleotides
5’-Fluorescent labeled oligo: 10,000 picomoles
Catalog: 450007
Size: 10,000 pmol
Category: Products & Services > Labeling & Detection Products > Labels & Labeling Kits > Cell, Tissue, & In Vivo Labeling Reagents
Molecular Probes® CellTracker™ fluorescent probes freely pass through cell membranes and are converted to cell-impermeant reaction products. The cell-impermeant form is passed to daughter cells through several generations but is not transferred to adjacent cells in the population. Cells that are loaded with CellTracker™ probes are typically fluorescent and viable for at least 24 hours, making these probes excellent long-term cell tracers. Furthermore, the staining pattern can be fixed with formaldehyde or glutaraldehyde to allow long-term storage of the labeled cells or tissue, to facilitate s...
Catalog: C2110
Size: 5 mg
Category: Products & Services > Kits & Assays > Cell Analysis Kits > Autophagy Detection Kits
The Premo™ Autophagy Sensor RFP-p62 Kit combines the ability to monitor the induction or inhibition of autophagy, through the localization of the autophagy receptor p62 (also known as SQSTM1), with the high transduction efficiency and minimal toxicity of BacMam 2.0 technology. To perform an image-based analysis for autophagy, simply add the BacMam 2.0 RFP-p62 reagent to your mammalian cells, incubate overnight to ensure adequate protein expression, and then visualize using standard RFP (red fluorescent protein) settings. The RFP gene included in this chimera is mKate2. This monomeric fluoresce...
Catalog: P36241
Size: 1 kit
Category: Products & Services > Kits & Assays > Cell Analysis Kits > Autophagy Detection Kits
The Premo™ Autophagy Sensor GFP-p62 Kit combines the ability to monitor the induction or inhibition of autophagy, through the localization of the autophagy receptor p62 (also known as SQSTM1), with the high transduction efficiency and minimal toxicity of BacMam 2.0 technology. To perform an image-based analysis for autophagy, simply add the BacMam 2.0 GFP-p62 reagent to your mammalian cells, incubate overnight to ensure adequate protein expression, and then visualize using standard GFP (green fluorescent protein) settings. The GFP gene included in this chimera is TagGFP2, which has been demons...
Catalog: P36240
Size: 1 kit
Category: Products & Services > Kits & Assays > Cell Analysis Kits > Autophagy Detection Kits
The Premo™ Autophagy Tandem Sensor RFP-GFP-LC3B Kit combines the ability to monitor the various stages of autophagy (through LC3B protein localization) with the high transduction efficiency and minimal toxicity of BacMam 2.0 expression technology. To perform image-based analysis for autophagy, simply add the BacMam 2.0 RFP-GFP-LC3B reagent to your mammalian cells, incubate overnight to ensure maximum protein expression, and then visualize using standard GFP (green fluorescent protein) and RFP (red fluorescent protein) settings. This tandem RFP-GFP sensor capitalizes on the pH difference betwee...
Catalog: P36239
Size: 1 kit
Category: Products & Services > Kits & Assays > Enzyme Detection & Activity Assays > Other Enzyme Assay Kits
The NA-Fluor™ Influenza Neuraminidase Assay Kit provides validated reagents and a standardized protocol for conducting neuraminidase enzyme assays, including neuraminidase inhibitor (NI) susceptibility screening using a fluorescent MUNANA substrate. Key product features: • Efficient design—neuraminidase assay in one complete kit • Optimized formulations—assay reagents have been optimized for maximum performance based on NISN protocols • Robust application—functional detection of NI-resistant virus in mixed viral populations • Easy of use & flexible screening—stable fluorescent signal enables b...
Catalog: 4457091
Size: 960 assays
Category: Products & Services > Kits & Assays > Sequencing Kits & Reagents > Sequencing Kits
The BigDye® Terminator v3.1 Cycle Sequencing Kit's robust, highly flexible chemistry is ideal for de novo sequencing, resequencing, and finishing with PCR product, Plasmid, Fosmid, and BAC templates. • Improve the quality of your results for a wide range of sequencing applications. • Optimized for long read lengths. • Better dye mobility characteristics • Improved performance reading through GT rich regions. • Get longer, higher-quality reads with more uniform peak heights and optimal signal balance. • Enhance your productivity and reduce costs. Get More Uniform Peak Heights, Improved Accuracy...
Catalog: 4337458
Size: 25000 reactions
Category: Products & Services > Kits & Assays > Real-Time PCR & Endpoint RT-PCR Kits > qPCR Protein Analysis Kits
Applied Biosystems® Protein Thermal Shift™ kits allow users to employ a dye that binds to exposed hydrophobic residues to monitor the thermal stability of proteins using a real-time PCR instrument in order to identify buffer conditions that stabilize the protein of interest or screen libraries of ligands for compounds that bind the protein of interest. Save Time and Money with Your Sample Screening This solution significantly reduces the time and cost associated with screening samples relative to currently available methods. Protein Thermal Shift™ products that are run on our real-time PCR sys...
Catalog: 4462263
Size: 2000 reactions
Category: Products & Services > Kits & Assays > Enzyme Detection & Activity Assays > Other Enzyme Assay Kits
The EnzChek® Lysozyme Assay Kit provides researchers with a simple and sensitive assay to measure lysozyme acitivty in solution. The assay measures lysozyme activity on Micrococcus lysodeikticus cell walls, which are labeled to such a degree with fluorescein that the fluorescence is quenched. Lysozyme action can relieve this quenching, yielding a dramatic increase in fluorescence that is proportional to lysozyme activity.
Catalog: E22013
Size: 1 kit
Category: Products & Services > Kits & Assays > Impurity & Contamination Detection Kits > Mycoplasma Detection Kits
The MycoFluor™ Mycoplasma Detection Kit provides an ultrasensitive, rapid and simple fluorescence microscopic acid for the visual identification of mycoplasma infection in laboratory cell cultures. In order to detect mycoplasma, the fluorescent MycoFluor™ reagent is added directly to the culture medium, with or without cells, and the stained sample is then examined under a fluorescence microscope.
Catalog: M7006
Size: 1 kit