Category: Products & Services > Instruments, Software, & Accessories > Plates & Accessories > Adhesive Film & Other Plate-Related Accessories
This precision plate holder is for use with Applied Biosystems® 7300 real-time PCR systems (SN 273000878 and above), as well as 7500 real-time PCR systems (SN 275001330 and above). Customers with earlier serial numbers should contact Product Support .
Catalog: 4367032
Size: 1 each
Category: Products & Services > Controls, Standards & Ladders > Instrument Calibration Kits, Standards & Reagents > Real-Time PCR Instrument Calibration Kits & Reagents
The 7300 & 7500 Real-Time PCR Systems TaqMan® RNase P Instrument Verification Plate is used to verify the performance of the Applied Biosystems® 7300 and 7500 Real-Time PCR Systems. The 7300 & 7500 Real-Time PCR Systems TaqMan® RNase P Instrument Verification Plate is a 96-well PCR plate preloaded with the necessary reagents to detect and quantitate genomic copies of the human RNase P gene, a single-copy gene encoding the RNA moiety of the RNase P enzyme. Each well contains preloaded reaction mix (1X TaqMan® Universal PCR Master Mix, RNase P primers, and FAM™ dye–labeled probe) and template. T...
Catalog: 4350584
Size: 1 kit
Category: Products & Services > Antibodies & Secondary Detection Reagents > Isotype Antibody Controls
Properly controlled IHC stains require that a non-immune immunoglobulin equivalent of the primary antibody be run on the sample tissue in the same way that the primary antibody is run. Any positive staining would indicate that the primary antibody stain may not be specific. These reagents can be used as negative isotype controls for our predilute primary antibodies.
Catalog: 08-6199
Size: 18 ml
Category: Products & Services > Controls, Standards & Ladders > Control Serum, Cell Extracts, & Related Standards
AB-Human Serum (heat-inactivated)
Catalog: 34005-100
Size: 100 ml
Category: Products & Services > Slide & Chip Arrays
AB-TUBE-ANTI--MYC
Catalog: 460603
Size: 1 each
Category: Products & Services > Kits & Assays > Sequencing Kits & Reagents > Library Preparation Kits for Sequencing
The Ion Total RNA-Seq Kit for AB Library Builder™ System combines optimized reagents and protocols for automated preparation of representative cDNA libraries for strand-specific RNA sequencing of all types of RNA species on the Ion Personal Genome Machine (PGM™) and Proton™ sequencers. Either small RNA (such as microRNA) or whole transcriptome RNA samples can be prepared for next-generation sequencing. The Ion Total RNA-Seq Kit for AB Library Builder™ System contains the same performance advantages as the manual Ion Total RNA-Seq Kit v2 with the convenience of protocol automation. The gel size...
Catalog: 4482416
Size: 13 reactions
Category: Products & Services > Instruments, Software, & Accessories > Instrument Accessories > Sequencing & Genetic Analyzer Instrument Accessories
The Ion Total RNA Library Protocol Card for AB Library Builder™System is required for running the Ion Total RNA-Seq Kit for AB for Library Builder™System . This protocol card contains the firmware needed to easily automate the creation of up to 13 whole transcriptome or small RNA (miRNA) libraries upstream of semiconductor sequencing on either the Ion PGM™ or Ion Proton™ platforms. The Ion Total RNA Library Protocol Card for AB Library Builder™System: • Enables whole transcriptome or small RNA (miRNA) library construction on the AB Library Builder™System • Eliminates the need for instrument pr...
Catalog: 4482563
Size: 1 card
Category: Products & Services > Kits & Assays > Real-Time PCR & Endpoint RT-PCR Kits > qPCR Kits
Applied Biosystems® TaqMan® Universal PCR Master Mix, No AmpErase® UNG is the ideal reagent solution when you need a Master Mix for multiple 5' nuclease DNA applications. Applied Biosystems® reagents have been validated with TaqMan® Assays and Applied Biosystems® real-time systems to ensure sensitive, accurate, and reliable performance every time. • Contains AmpliTaq Gold® DNA polymerase to provide a better yield and a more robust 5' nuclease assay than AmpliTaq® DNA polymerase • Includes a passive internal reference based on proprietary ROX™ dye, for superb precision on Applied Biosystems® re...
Catalog: 4364341
Size: 400 reactions
Category: Products & Services > Kits & Assays > Real-Time PCR & Endpoint RT-PCR Kits > qPCR Kits
Applied Biosystems® TaqMan® Universal PCR Master Mix, No AmpErase® UNG is the ideal reagent solution when you need a Master Mix for multiple 5' nuclease DNA applications. Applied Biosystems® reagents have been validated with TaqMan® Assays and Applied Biosystems® real-time systems to ensure sensitive, accurate, and reliable performance every time. • Contains AmpliTaq Gold® DNA polymerase to provide a better yield and a more robust 5' nuclease assay than AmpliTaq® DNA polymerase • Includes a passive internal reference based on proprietary ROX™ dye, for superb precision on Applied Biosystems® re...
Catalog: 4326614
Size: 2000 reactions
Category: Products & Services > Kits & Assays > Genotyping Kits > SNP Genotyping Kits
The TaqMan® GTXpress™ Master Mix delivers accurate genotyping results with robust performance in less than 50 min. Applied Biosystems® TaqMan® GTXpress™ Master Mix (2X) combines AmpliTaq® Fast DNA Polymerase, UP, dNTPs, Tracking Dye, and ROX™ dye in a convenient single vial format. The 1 mL pack includes reagents sufficient to perform 400 PCR reactions (5 µL/reaction). • Compatible with both Fast and Standard mode thermal cycling conditions • Pre-mixed components stored at 2°–8°C significantly reduce assay setup time • Validated with all types of Applied Biosystems® TaqMan® Genotyping Assays •...
Catalog: 4403311
Size: 400 reactions
Category: Products & Services > Instruments, Software, & Accessories > Software > Real-Time PCR Software
The Primer Express® Software v3.0.1 allows you to design your own primers and probes using TaqMan® and SYBR® Green I dye chemistries for gene quantitation and allelic discrimination (SNP) real-time PCR applications. Developed specifically for use with our StepOne®, StepOnePlus®, 7300, 7500, 7500 Fast, 7900HT, ViiA™ 7, and QuantStudio™ real-time PCR systems, Primer Express® Software provides customized application-specific documents for absolute⁄relative quantitation and allelic discrimination. • Enables individual oligonucleotide design for real-time PCR applications. • Supports assays based o...
Catalog: 4363993
Size: 1 license
Category: Products & Services > Kits & Assays > Real-Time PCR & Endpoint RT-PCR Kits > qPCR Kits
Applied Biosystems® TaqMan® Universal PCR Master Mix is the ideal reagent solution when you need a Master Mix for multiple 5' nuclease DNA applications. Applied Biosystems® reagents have been validated with TaqMan® Assays and Applied Biosystems® real-time systems to ensure sensitive, accurate, and reliable performance every time. • Contains AmpliTaq Gold® DNA polymerase to provide a better yield and a more robust 5' nuclease assay than AmpliTaq® DNA polymerase • Includes a passive internal reference based on proprietary ROX™ dye, for superb precision on Applied Biosystems® real-time PCR instru...
Catalog: 4304437
Size: 200 reactions
Category: Products & Services > Kits & Assays > Real-Time PCR & Endpoint RT-PCR Kits > qPCR Kits
Get superior nucleic acid quantitation with Applied Biosystems® Power SYBR® Green Master Mix. Power SYBR® Master Mix offers superior sensitivity and reproducibility, detecting as few as two copies of a target gene over a broad range of template concentrations. • Everything you need for SYBR® Green dye–based PCR amplification and detection in a convenient single-tube format. Power SYBR® Green PCR Master Mix contains all of the components, excluding the template and primers, for superior SYBR® Green reagent-based real-time PCR • The optimized formulation contains highly purified AmpliTaq Gold® D...
Catalog: 4367659
Size: 200 reactions
Category: Products & Services > Instruments, Software, & Accessories > Plates & Accessories > PCR Plates
The Applied Biosystems® MicroAmp® Optical 96-Well Reaction Plate is optimized to provide unmatched temperature accuracy and uniformity for fast, efficient PCR amplification. This plate, constructed from a single rigid piece of polypropylene in a ninety-six well format is compatible with Applied Biosystems® 96-Well Real-Time PCR Systems and Thermal Cyclers. • Frosted to minimize interfering fluorescence from wells of cycling block in real-time PCR applications • Screened to eliminate auto-fluorescent plates • Unique design provides a barrier to ambient air to help insure well-to-well temperatur...
Catalog: N8010560
Size: 10 plates
Category: Products & Services > Instruments, Software, & Accessories > Plates & Accessories > Adhesive Film & Other Plate-Related Accessories
The Applied Biosystems® MicroAmp® Optical Adhesive Film reduces the chance of well-to-well contamination and sample evaporation when applied to a microplate. • Pressure-sensitive adhesive provides a tight seal over every well • Will not interfere with sample reading • Press-N-Seal: Align properly to the plate, then press to seal • Easy to apply-will not stick to your glove Prevent Loss of Precious Samples Use this optically-clear adhesive film to seal the samples into the wells of a microplate. This will reduce the possibility of cross-contamination between sample wells and help ensure consist...
Catalog: 4360954
Size: 25 covers
Category: Products & Services > Kits & Assays > Real-Time PCR & Endpoint RT-PCR Kits > qPCR Kits
Everything you need for SYBR® Green dye–based PCR amplification and detection in a convenient, single-tube format. Applied Biosystems® SYBR® Green PCR Master Mix combines SYBR® Green I dye, AmpliTaq Gold® DNA Polymerase, dNTPs with dUTP, Passive Reference 1, and optimized buffer in the convenience of a single vial. • Premixed components stored at 2–8°C significantly reduce assay setup time • SYBR® Green I dye detects double-stranded DNA, so specific probes are not required • AmpliTaq Gold® DNA polymerase minimizes nonspecific product formation to achieve superior performance • dUTP significant...
Catalog: 4309155
Size: 200 reactions
Category: Products & Services > Instruments, Software, & Accessories > Plates & Accessories > Adhesive Film & Other Plate-Related Accessories
The Applied Biosystems® MicroAmp® 96-Well Tray for VeriFlex™ Blocks is specifically designed to snugly hold MicroAmp® Fast Reaction Tubes with Caps and MicroAmp® Fast 8-Tube Strips (0.1 mL) in a 96-well format. They are also designed to snugly hold MicroAmp® Reaction Tubes with Caps (0.2 mL). Engineered for efficient sample processing Designed specifically for MicroAmp® Fast Reaction Tubes with Caps (0.1 mL) and MicroAmp® Fast 8-Tube Strips (0.1 mL) Designed specifically for MicroAmp® Reaction Tubes with Caps (0.2 mL) Manufactured to high specification, ensuring a quality product Convenience a...
Catalog: 4379983
Size: 10 trays
Category: Products & Services > Kits & Assays > Real-Time PCR & Endpoint RT-PCR Kits > qPCR Kits
This kit contains components needed to perform up to 1000 assays using TaqMan® probes. The kit employs AmpliTaq Gold® DNA polymerase for enhanced performance, 10X TaqMan Buffer A, and magnesium chloride. The components are provided in bulk and enable flexibility in assay setup. Separate Components Provide Flexibility in Assay Set-Up AmpliTaq Gold® DNA polymerase increses yield and gives a more robust 5' nuclease assay than AmpliTaq® DNA polymerase. Passive Reference I in the 10X TaqMan® Buffer A normalizes signal in all TaqMan® Assay reactions and corrects inter-well signal variation caused by...
Catalog: 4304441
Size: 1000 reactions
Category: Products & Services > Instruments, Software, & Accessories > Plates & Accessories > Adhesive Film & Other Plate-Related Accessories
Applied Biosystems® MicroAmp® Optical Film Compression Pads are designed to support a proper thermal seal between the thermal cycler and reaction plates when using adhesive films. Note: See user's manual or package insert for limited label license, and trademark information. For Research Use Only. Not for use in diagnostics procedures.
Catalog: 4312639
Size: 5 each
Category: Products & Services > Instruments, Software, & Accessories > Software > Real-Time PCR Software
The Primer Express® Software v3.0.1 allows you to design your own primers and probes using TaqMan® and SYBR® Green I dye chemistries for gene quantitation and allelic discrimination (SNP) real-time PCR applications. Developed specifically for use with our StepOne®, StepOnePlus®, 7300, 7500, 7500 Fast, 7900HT, ViiA™ 7, and QuantStudio™ real-time PCR systems, Primer Express® Software provides customized application-specific documents for absolute⁄relative quantitation and allelic discrimination. • Enables individual oligonucleotide design for real-time PCR applications. • Supports assays based o...
Catalog: 4363991
Size: 1 license