Category: Products & Services > Labeling & Detection Products > Sensors & Indicators > Ion Indicators & Ionophores
Our highly purified lucigenin is a fluorescent Cl- indicator that has excitation/emission maxima of 368/505 nm and whose fluorescence is quenched in the presence of Cl-. The dye is useful for determining Cl- concentrations in liposomes, reconstituted membranes or in extracellular medium but is not useful for intracellular measurements.
Catalog: L6868
Size: 10 mg
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers
NuPAGE® Novex Tris-Acetate Gels provide excellent separation of large molecular weight proteins when used with NuPAGE® Tris-Acetate SDS Running Buffer. NuPAGE® Novex Tris-Acetate gels can also be run with Tris-Glycine Native Running Buffer to resolve native proteins more effectively than the Tris-Glycine gel system. Formulation: NuPAGE® Novex Tris-Acetate gels are made with high-purity, strictly quality-controlled reagents: Tris base, acetic acid, acrylamide, bis-acrylamide, TEMED, APS, and highly purified water. They do not contain SDS. Recommended Buffers: Run NuPAGE® Novex Tris-Acetate gels...
Catalog: LA0041
Size: 500 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Sample Buffers
NuPAGE® Novex 3-8% Tris-Acetate Midi-Gels provide excellent separation of large molecular weight proteins when used with NuPAGE® Tris-Acetate SDS Running Buffer. NuPAGE® Novex Tris-Acetate gels can also be run with Tris-Glycine Native Running Buffer to resolve native proteins more effectively than the Tris-Glycine gel system. NuPAGE® Novex Tris-Acetate Midi-Gels (8 x 13 cm) can run up to 26 samples. The NuPAGE Midi-Gels run in the XCell4 Surelock™ Midi-Cell and, with a Midi Gel Adapter, can run in a Bio-Rad Criterion Cell. Formulation: NuPAGE® Novex Tris-Acetate gels are made with high-purity,...
Catalog: LA0050
Size: 1 kit
Category: Products & Services > Kits & Assays > Microbial Detection & Identification Kits
Same as TaqVet Lawsonia intracellularis Real-Time PCR Kit (LAWP/50) TaqMan® probes - DNA - duplex - One well reaction Real-time PCR enables sensitive and specific detection of pathogen nucleic acid in animal samples, allowing for reliable and rapid screening and detection of infected animals. The LSI VetMAX™ kits include: • 1 ready-to-use mix that includes a set of oligonucleotides for detection of the target gene OR these separate components that will need to be mixed together: a set of oligonucleotides for the detection of the target gene + a TaqMan® real-time PCR master mix + an RT enzyme (...
Catalog: LAWP50
Size: 50 tests
Category: Products & Services > Instruments, Software, & Accessories > Tips, Tubes, Strips & Accessories > Tips
Invitrogen offers a variety of tips for easy and accurate loading of samples. They are RNase/DNase-free and non-autoclavable.
Catalog: LC1002
Size: 200⁄pack
Category: Products & Services > Gels, Fractionation Strips, & Membranes > Blotting Membranes > PVDF Membranes
Invitrogen makes blotting easier by providing a variety of pre-cut, pre-assembled membrane/filter-paper sandwiches. A protein's properties ( i.e. , charge, hydrophobicity, etc.) affect its ability to bind to membrane surfaces. Finding the right membrane may require experimenting with your specific protein on different membranes. Store all membranes at room temperature.
Catalog: LC2002
Size: 20⁄pack
Category: Products & Services > Gels, Fractionation Strips, & Membranes > Blotting Membranes > PVDF Membranes
Invitrogen makes blotting of E-PAGE™ Gels easier and more efficient by providing a pre-cut fiber blotting pad and several types of pre-cut, pre-assembled membrane/filter paper sandwiches that perfectly fit 8.6 cm x 13.5 cm E-PAGE™ Gels*. The available nitrocellulose and Invitrolon™ PVDF membranes are designed for western transfer of proteins (Figure 1, Table 1). Pre-cut, extra-thick, absorbent Blotting Paper (2.5 mm thickness) for E-PAGE" Gels are also available to accommodate the E-PAGE™ blotting set-up using a semi-dry transfer apparatus. A protein s properties affect its ability to bind to ...
Catalog: LC2007
Size: 16⁄pack
Category: Products & Services > Gels, Fractionation Strips, & Membranes > Blotting Membranes > Filter Paper
Invitrogen makes blotting of E-PAGE™ Gels easier and more efficient by providing a pre-cut fiber blotting pad and several types of pre-cut, pre-assembled membrane/filter paper sandwiches that perfectly fit 7.5 cm x 8.4 cm E-PAGE™ Gels*. The available nitrocellulose and Invitrolon™ PVDF membranes are designed for western transfer of proteins (Figure 1, Table 1). Pre-cut, extra-thick, absorbent Blotting Paper (2.5 mm thickness) for E-PAGE" Gels are also available to accommodate the E-PAGE™ blotting set-up using a semi-dry transfer apparatus. A protein s properties affect its ability to bind to m...
Catalog: LC2010
Size: 50 sheets
Category: Products & Services > Instruments, Software, & Accessories > Gel Boxes, Gel Imagers, Power Supplies & Accessories > Gel Blotting, Drying & Staining Accessories
The Blotting Roller is an 8.6 cm wide roller designed for easy and efficient removal of bubbles when assembling gel/membrane sandwiches for blotting both E-PAGE™ Gels and mini-gels such as NuPAGE® and Novex¤ Tris-Glycine Gels. It consists of a Delrin roller attached to a stainless steel handle. The Incubation Tray enables convenient and even staining of E-PAGE™ blots. The tray is 10 cm (l) x 14 cm (w) x 3 cm (d) with a lid. It is suitable for use with immunodetection or blot stains.
Catalog: LC2100
Size: 1 unit
Category: Products & Services > Instruments, Software, & Accessories > Gel Boxes, Gel Imagers, Power Supplies & Accessories > Gel Blotting, Drying & Staining Accessories
Invitrogen makes blotting of E-PAGE™ Gels easier and more efficient by providing a pre-cut fiber blotting pad and several types of pre-cut, pre-assembled membrane/filter paper sandwiches that perfectly fit 8.6 cm x 13.5 cm E-PAGE™ Gels*. The available nitrocellulose and Invitrolon™ PVDF membranes are designed for western transfer of proteins (Figure 1, Table 1). Pre-cut, extra-thick, absorbent Blotting Paper (2.5 mm thickness) for E-PAGE" Gels are also available to accommodate the E-PAGE™ blotting set-up using a semi-dry transfer apparatus. A protein s properties affect its ability to bind to ...
Catalog: LC2101
Size: 4 pads
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Running Buffers
Novex® Tris-Glycine polyacrylamide gel chemistry is based on the Laemmli system (1) with minor modifications for maximum performance in the pre-cast format. These gels do not contain SDS and can therefore be used to accurately separate both native and denatured proteins. Novex® Tris-Glycine Gels provide reproducible separation of a wide range of proteins into well-resolved bands. Formulation: Novex® Tris-Glycine Gels are made with high-purity, strictly quality-controlled reagents: Tris base, HCl, acrylamide, bisacrylamide, TEMED, APS, and highly purified water. They do not contain SDS. Recomme...
Catalog: LC2675-5
Size: 5 L
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Sample Buffers
Novex® Tris-Glycine polyacrylamide gel chemistry is based on the Laemmli system (1) with minor modifications for maximum performance in the pre-cast format. These gels do not contain SDS and can therefore be used to accurately separate both native and denatured proteins. Novex® Tris-Glycine Gels provide reproducible separation of a wide range of proteins into well-resolved bands. Formulation: Novex® Tris-Glycine Gels are made with high-purity, strictly quality-controlled reagents: Tris base, HCl, acrylamide, bisacrylamide, TEMED, APS, and highly purified water. They do not contain SDS. Recomme...
Catalog: LC2676
Size: 20 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Protein Gel Buffers > Protein Gel Transfer Buffers
Novex® Tris-Glycine Transfer Buffer (25X) is specially optimized for western blot transfer applications using Tris-Glycine gels.
Catalog: LC3675
Size: 500 ml
Category: Products & Services > Controls, Standards & Ladders > Protein Standards & Ladders > Western Blot Protein Standards
The MagicMark™ XP Western Protein Standard is specifically designed for easy and convenient protein molecular weight estimation directly on western blots. The standard consists of 9 recombinant proteins each of which contains an IgG binding site. The IgG binding site binds the primary or secondary antibody used for detection of the target protein allowing direct visualization of the standard on the western blot. The MagicMark™ XP Standard is compatible with all western kits and substrates (chemiluminescent, chromogenic and fluorescent) and offers: • Direct visualization of molecular weight sta...
Catalog: LC5602
Size: 250 µl
Category: Products & Services > Controls, Standards & Ladders > Protein Standards & Ladders > Unstained Protein Standards
The HiMark™ Unstained High Molecular Weight (HMW) Protein Standard is designed for analysis of high molecular weight proteins on Novex® NuPAGE® Tris-Acetate Gels . • Comprehensive – Contains markers with a wide range of high molecular weights, providing 9 protein bands in the range of 30-460 kDa • Convenient – A ready-to-use formulation eliminates the need to heat, reduce, or add sample buffer prior to use • Compatible – Intended for use with NuPAGE® Novex 3-8% and 7% Tris-Acetate Gels under denaturing conditions* *Note: HiMark™ Unstained High Molecular Weight Protein Standard can also be used...
Catalog: LC5688
Size: 250 µl
Category: Products & Services > Controls, Standards & Ladders > Protein Standards & Ladders > Prestained Protein Standards
The SeeBlue® Plus2 Pre-Stained Standard has been optimized for compatibility with NuPAGE® and Bolt™ gels, which use Life Technologies' Bis-Tris gel formulation. The SeeBlue® Plus2 Pre-Stained Standard contains 10 proteins: eight blue-dyed proteins and two proteins with contrasting colors, allowing easier band identification. The SeeBlue® Plus2 Standard allows you to easily monitor molecular weight ranges during electrophoresis and quickly evaluate Western transfer efficiency. The SeeBlue® Plus2 Standard offers: • 10 polypeptides resolved into 8 blue and 2 colored bands in the range of 4–250 kD...
Catalog: LC5925
Size: 500 µl
Category: Products & Services > Labeling & Detection Products > Gel & Membrane Stains
InVision™ His-tag In-gel Stain is a ready-to-use, fast, sensitive and highly specific stain for visualizing His-tagged fusion protein bands directly in a polyacrylamide gel following electrophoresis. Using InVision™ His-tag In-gel Stain you'll: Stain proteins fused to an oligohistidine sequence Eliminate western blotting-detect His-tagged proteins directly in the gel Detect nanogram levels of protein bands with a UV transilluminator, equipped with a standard camera, or a laser-based scanner Visualize results in under 3 hours Convenienty provided as one ready-to-use solution, InVision™ His-tag ...
Catalog: LC6030
Size: 500 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Nucleic Acid Gel Loading Buffers
Novex® TBE Gels provide the highest resolution possible for analyzing restriction digests and PCR products. DNA fragments ranging from 10 to 3,000 base pairs are clearly resolved into sharp, tight bands. Novex® DNA Retardation gels are prepared with 0.5X TBE as the gel buffer. This is sufficient for good electrophoretic separation, yet low enough to promote DNA-protein interactions. Novex® TBE and DNA Retardation Gels are designed to run on the XCell SureLock ™ Mini-Cell. Formulation: Novex® TBE and DNA Retardation Gels are manufactured with high-purity tris base, boric acid, EDTA, acrylamide,...
Catalog: LC6678
Size: 10 ml
Category: Products & Services > Buffers & Chemicals > Electrophoresis Reagents & Buffers > Nucleic Acid Gel Loading Buffers
Denaturing polyacrylamide TBE-Urea Gels resolve single-stranded DNA oligos or RNA into sharp, distinct bands. Novex® TBE-Urea Gels are optimized for the analysis and purification of products ranging from 20-800 bases, making them an ideal choice for synthetic oligo analysis and purification, RNase Protection Assays (RPA), in vitro transcription studies, and Northern blot analysis. Novex® TBE-Urea Gels are designed to run on the XCell SureLock ™ Mini-Cell. Formulation: Novex® TBE-Urea Gels are made with high-purity reagents, including tris base, boric acid, EDTA, acrylamide, bisacrylamide, TEME...
Catalog: LC6876
Size: 10 ml
Category: Products & Services > Instruments, Software, & Accessories > Instrument Accessories > Counting, & Flow Cytometer Accessories
Specially designed for use with the ARCTURUS® Laser Capture Microdissection (LCM) instruments, CapSure® HS and CapSure® Macro LCM Caps enable the precise and rapid extraction of pure populations of cells from heterogeneous sample preparations. CapSure Caps may be used to isolate individual cells or thousands of cells on a single cap. Key product features: • Gentle application – non-damaging microdissection preserves the integrity of the captured material • Versatile extraction – capture both large and small amounts of cells Ensure the Integrity of Microdissected Cells for Downstream Molecular ...
Catalog: LCM0214
Size: 32 caps
Category: Products & Services > Instruments, Software, & Accessories > Imaging & Microscopy Accessories > Microscopy Accessories
ARCTURUS® laser capture microdissection (LCM) instruments offer a unique combination of infrared (IR) laser capture and ultraviolet (UV) laser cutting, permitting the use of any slide type and any sample preparation for microdissection. While plain glass slides are effectively used for standard IR-based LCM, polyethylene naphthalate (PEN) membrane slides facilitate this Arcturus®-exclusive dual laser function and allow you to determine the appropriate sample preparation based on your application need. Plain Glass Slides The ARCTURUS® instruments are the only LCM systems that allow efficient us...
Catalog: LCM0522
Size: 50 each
Category: Products & Services > Instruments, Software, & Accessories > Imaging & Microscopy Accessories > Microscopy Accessories
A suite of accessories has been designed to enable research on living cells using your ArcturusXT™ LCM Instrument. Researchers may use slides or Petri dishes to perform imaging and microdissection experiments. Following a validated protocol from Arcturus® LCM Systems from Applied Biosystems—the leaders in tissue-based microdissection—the live cells may be isolated, remaining viable for subsequent re-culture or direct processing for use in downstream applications. Polyethylene naphthalate (PEN) Membrane Frame Slides for Live Cell Microdissection • Specially optimized for use with live cell expe...
Catalog: LCM0531
Size: 25 each
Category: Products & Services > Kits & Assays > Microbial Detection & Identification Kits
Same as TaqVet PathoLept(TM) Real-Time PCR Kit (LEPT/50) TaqMan® probes - DNA - duplex - One well reaction Real-time PCR enables sensitive and specific detection of pathogen nucleic acid in animal samples, allowing for reliable and rapid screening and detection of infected animals. The LSI VetMAX™ kits include: • 1 ready-to-use mix that includes a set of oligonucleotides for detection of the target gene OR these separate components that will need to be mixed together: a set of oligonucleotides for the detection of the target gene + a TaqMan® real-time PCR master mix + an RT enzyme (only for RN...
Catalog: LEPT50
Size: 50 tests
Category: Products & Services > Kits & Assays > Microbial Detection & Identification Kits
Test 12 samples for Rotaviurs, Coronavirus, E. coli, and Cryptosporidium. Two-well Antigen-capture ELISA kits enable sensitive and specific detection of pathogens in animal samples, allowing for reliable and rapid screening and detection of infected animals. How the kit works: 1. Samples are added to the microplate coated with anti-pathogen antibodies. If present in the sample, specific antigen binds to the anti-pathogen antibodies and form antigen-antibody complexes. 2. After washing, an anti-pathogen peroxidase-labeled conjugate is added, which binds to any antigens attached to the plate. 3....
Catalog: LSIDTT
Size: 12 tests
Category: Products & Services > Kits & Assays > Microbial Detection & Identification Kits
Same as LSIDTT Two-well antigen-capture ELISA kits enable sensitive and specific detection of pathogens in animal samples, allowing for reliable and rapid screening and detection of infected animals. How the kit works: 1. Samples are added to the microplate coated with anti-pathogen antibodies. If present in the sample, specific antigen binds to the anti-pathogen antibodies and form antigen-antibody complexes. 2. After washing, an anti-pathogen peroxidase-labeled conjugate is added, which binds to any antigens attached to the plate. 3. After a second washing, a chromogenic substrate is added. ...
Catalog: LSIDTT1
Size: 12 tests
Category: Products & Services > Kits & Assays > Microbial Detection & Identification Kits
Same as LSINEOA/2 Single-well Indirect ELISA kits enable sensitive and specific detection of pathogen-specific antibodies in animal samples, allowing for reliable and rapid screening and detection of seropositive animals. How the kit works: 1. Samples are added to the specific antigen-coated microplate. If present in the sample, specific anti-pathogen antibodies bind to the antigen and form antigen-antibody complexes. 2. After washing, an anti-species peroxidase-labeled conjugate is added, which binds to any antibodies attached to the plate. 3. After a second washing, a chromogenic substrate i...
Catalog: LSINEOA2
Size: 192 tests
Category: Products & Services > Kits & Assays > Microbial Detection & Identification Kits
Same as LSINEOA/5 Single-well Indirect ELISA kits enable sensitive and specific detection of pathogen-specific antibodies in animal samples, allowing for reliable and rapid screening and detection of seropositive animals. How the kit works: 1. Samples are added to the specific antigen-coated microplate. If present in the sample, specific anti-pathogen antibodies bind to the antigen and form antigen-antibody complexes. 2. After washing, an anti-species peroxidase-labeled conjugate is added, which binds to any antibodies attached to the plate. 3. After a second washing, a chromogenic substrate i...
Catalog: LSINEOA5
Size: 480 tests
Category: Products & Services > Kits & Assays > Microbial Detection & Identification Kits
Single-well Indirect ELISA kits enable sensitive and specific detection of pathogen-specific antibodies in animal samples, allowing for reliable and rapid screening and detection of seropositive animals. How the kit works: 1. Samples are added to the specific antigen-coated microplate. If present in the sample, specific anti-pathogen antibodies bind to the antigen and form antigen-antibody complexes. 2. After washing, an anti-species peroxidase-labeled conjugate is added, which binds to any antibodies attached to the plate. 3. After a second washing, a chromogenic substrate is added. Color dev...
Catalog: LSINEOASL2
Size: 192 tests
Category: Products & Services > Kits & Assays > Microbial Detection & Identification Kits
Same as LSINEOASL/5 Single-well Indirect ELISA kits enable sensitive and specific detection of pathogen-specific antibodies in animal samples, allowing for reliable and rapid screening and detection of seropositive animals. How the kit works: 1. Samples are added to the specific antigen-coated microplate. If present in the sample, specific anti-pathogen antibodies bind to the antigen and form antigen-antibody complexes. 2. After washing, an anti-species peroxidase-labeled conjugate is added, which binds to any antibodies attached to the plate. 3. After a second washing, a chromogenic substrate...
Catalog: LSINEOASL5
Size: 480 tests
Category: Products & Services > Labeling & Detection Products > Sensors & Indicators > Reactive Oxygen & Nitrogen Species
MTT is used to assess cell viability as a function of redox potential. Actively respiring cells convert the water-soluble MTT to an insoluble purple formazan. The formazan is then solubilized and its concentration determined by optical density.
Catalog: M-6494